Gas Discharge Tube: GD5 Series
2-Electrode Φ5.5 x T6 mm Type
Features
1. RoHS & HF compliant
2. Rugged ceramic-metal construction
3. Available with or without leads
4. DC spark-over voltage: 70~3600V
5. Low capacitance
6. Agency recognition: UL / cUL
7. Operating temperature : -40℃ ~ +85℃
Storage temperature: -40℃ ~ +115℃
Recommended Applications
1. Cable Modem
2. xDSL
3. Set-Top Box
4. TV sets
5. Power supplier
6. Consumer electronics
Part Number Code
G
1
D
2
5
3
2
4
R
5
2
6
3
7
0
8
M
9
B
10
11
12
13
Lead Wire Style
Electrode Number
2R 2 Electrodes
Product Code
Packaging
Internal Control
Code
M
No Lead
B
Bulk
THINKING Gas
Discharge Tube
G
Reel
Taping
Y
Axial Lead
R
Pitch 7.5 mm
Formed Lead
C
Pitch 8.0 mm
Formed Lead
DC Spark-over
Voltage
Size
Φ5.5*T6 mm
D
E
D5
070
70V
230V
600V
1400V
3600V
Pitch 10.0mm
Formed Lead
230
600
14B
36B
THINKING ELECTRONIC INDUSTRIAL Co., LTD.
All specification are subject to change without notice.
18