欢迎访问ic37.com |
会员登录 免费注册
发布采购

BAT54C 参数 Datasheet PDF下载

BAT54C图片预览
型号: BAT54C
PDF下载: 下载PDF文件 查看货源
内容描述: 0.9 -A恒流电源带PFC的100W的LED [A 0.9-A Constant Current Supply with PFC for 100-W LED]
分类和应用: 二极管功率因数校正光电二极管
文件页数/大小: 17 页 / 436 K
品牌: TI [ TEXAS INSTRUMENTS ]
 浏览型号BAT54C的Datasheet PDF文件第5页浏览型号BAT54C的Datasheet PDF文件第6页浏览型号BAT54C的Datasheet PDF文件第7页浏览型号BAT54C的Datasheet PDF文件第8页浏览型号BAT54C的Datasheet PDF文件第10页浏览型号BAT54C的Datasheet PDF文件第11页浏览型号BAT54C的Datasheet PDF文件第12页浏览型号BAT54C的Datasheet PDF文件第13页  
www.ti.com
Test Procedure
6.4
Buck Disable
1.
2.
3.
4.
5.
6.
7.
Ensure the AC source is off.
Connect a DC source to J4, pins 1 and 2.
Set DC source to 0 V.
Apply power to the EVM per
Increase DC source to 3.3 V. This input can accept up to 12 V.
Observe output current, A1, drops to zero.
PFC voltage, V2, does not change.
6.5
Internal Dimming Function
1.
2.
3.
4.
5.
Ensure the AC source is off.
Ensure jumper is present on J3.
Apply power to the EVM per
Rotate R26 potentiometer slowly anti clockwise.
Observe output current on A1 reduce from nominal 0.9 A to 0.1 A. If LED string is attached observe
LED’s dim.
6.6
External Dimming Function
Ensure the AC source is off.
Ensure jumper is removed from J3.
Connect signal generator to J4, pins 3 and 2.
Set signal generator to generator a pulse from 0 V to 3.3 V at 200 Hz with variable duty cycle. Note
when the PWM signal is high the LED light is reduced. 100% duty cycle will turn LED off.
5. Apply power to the EVM per
6. Vary the duty cycle of the signal generator output.
7. Observe output current, A1, changes. If an LED string is attached observe LED’s dim.
1.
2.
3.
4.
6.7
Configuring the PFC Stage for Fixed Output
The EVM ships configured as a boost follower PFC. Using a soldering iron some simple component
modifications can change the PFC configuration from boost follower to fixed output voltage.
1. Remove R1, R3, R4, R6, C1 and Q1.
2. Change R11 to 6.49 kΩ.
3. The EVM now uses a fixed output voltage PFC stage. Repeat tests to see functionality.
6.8
Equipment Shutdown
1.
2.
3.
4.
If DC sources are connected to shutdown pins, J2 and J4, ensure they are set to 0 V.
Ensure load is at maximum, this will help discharge C17.
Turn off AC source.
Monitor PFC output voltage V2. Do not handle EVM until V2 reads less than 50 VDC.
SLUU355A – March 2009 – Revised June 2009
A 0.9-A Constant Current Supply with PFC for 100-W LED Lighting Applications
9