CDC2586
3.3-V PHASE-LOCK LOOP CLOCK DRIVER
WITH 3-STATE OUTPUTS
SCAS337C – FEBRUARY 1993 – REVISED OCTOBER 1998
recommended operating conditions (see Note 3)
MIN
VCC
VIH
VIL
VI
IOH
IOL
Supply voltage
High-level input voltage
Low-level input voltage
Input voltage
High-level output current
Low-level output current
0
0
3
2
0.8
5.5
– 12
12
70
MAX
3.6
UNIT
V
V
V
V
mA
mA
°C
TA
Operating free-air temperature
NOTE 3: Unused inputs must be held high or low to prevent them from floating.
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
VIK
VOH
VOL
II
IOZH
IOZL
ICC
Ci
Co
VCC = 3 V,
VCC = MIN to MAX†,
VCC = 3 V,
VCC = 3 V
VCC = 0 or MAX†,
VCC = 3.6 V,
VCC = 3.6 V,
VCC = 3.6 V,
VCC = 3.6 V,
36V
VI = VCC or GND
VI = VCC or GND
VO = VCC or GND
TEST CONDITIONS
II = –18 mA
IOH = – 100
µA
IOH = – 12 mA
IOL = 100
µA
IOL = 12 mA
VI = 3.6 V
VI = VCC or GND
VO = 3 V
VO = 0
Outputs high
IO = 0
0,
Outputs low
Outputs disabled
TA = 25°C
MIN
MAX
–1.2
VCC – 0.2
2
0.2
0.8
±10
±1
10
– 10
1
1
1
4
8
pF
pF
mA
UNIT
V
V
V
µA
µA
µA
† For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
6
POST OFFICE BOX 655303
•
DALLAS, TEXAS 75265