欢迎访问ic37.com |
会员登录 免费注册
发布采购

DS90UR907QSQE 参数 Datasheet PDF下载

DS90UR907QSQE图片预览
型号: DS90UR907QSQE
PDF下载: 下载PDF文件 查看货源
内容描述: 5 - 65 MHz的24位彩色FPD -Link的以FPD -Link的II转换器 [5 - 65 MHz 24-bit Color FPD-Link to FPD-Link II Converter]
分类和应用: 转换器光电二极管
文件页数/大小: 27 页 / 527 K
品牌: TI [ TEXAS INSTRUMENTS ]
 浏览型号DS90UR907QSQE的Datasheet PDF文件第4页浏览型号DS90UR907QSQE的Datasheet PDF文件第5页浏览型号DS90UR907QSQE的Datasheet PDF文件第6页浏览型号DS90UR907QSQE的Datasheet PDF文件第7页浏览型号DS90UR907QSQE的Datasheet PDF文件第9页浏览型号DS90UR907QSQE的Datasheet PDF文件第10页浏览型号DS90UR907QSQE的Datasheet PDF文件第11页浏览型号DS90UR907QSQE的Datasheet PDF文件第12页  
DS90UR907Q
DC and AC Serial Control Bus Characteristics
Over 3.3V supply and temperature ranges unless otherwise specified.
Symbol
V
IH
V
IL
V
HY
V
OL
I
in
t
R
t
F
t
SU;DAT
t
HD;DAT
t
SP
C
in
SDA RiseTime – READ
SDA Fall Time – READ
Set Up Time — READ
Hold Up Time — READ
Input Filter
Input Capacitance
SDA or SCL
Parameter
Input High Level
Input Low Level Voltage
Input Hysteresis
SDA, IOL = 1.25mA
SDA or SCL, Vin = V
DDIO
or GND
SDA, RPU = 10kΩ, Cb
400pF,
0
-10
430
20
560
615
50
<5
SDA and SCL
SDA and SCL
Conditions
Min
0.7*
V
DDIO
GND
>50
0.36
+10
Typ
Max
V
DDIO
0.3*
V
DDIO
Units
V
V
mV
V
µA
ns
ns
ns
ns
ns
pF
Note 1:
“Absolute Maximum Ratings” indicate limits beyond which damage to the device may occur, including inoperability and degradation of device reliability
and/or performance. Functional operation of the device and/or non-degradation at the Absolute Maximum Ratings or other conditions beyond those indicated in
the Recommended Operating Conditions is not implied. The Recommended Operating Conditions indicate conditions at which the device is functional and the
device should not be operated beyond such conditions.
Note 2:
The Electrical Characteristics tables list guaranteed specifications under the listed Recommended Operating Conditions except as otherwise modified
or specified by the Electrical Characteristics Conditions and/or Notes. Typical specifications are estimations only and are not guaranteed.
Note 3:
Typical values represent most likely parametric norms at V
DD
= 3.3V, Ta = +25 degC, and at the Recommended Operation Conditions at the time of
product characterization and are not guaranteed.
Note 4:
Current into device pins is defined as positive. Current out of a device pin is defined as negative. Voltages are referenced to ground except VOD,
ΔVOD,
VTH and VTL which are differential voltages.
Note 5:
t
PLD
is the time required by the device to obtain lock when exiting power-down state with an active RxCLKIN.
Note 6:
UI – Unit Interval is equivalent to one serialized data bit width (1UI = 1 / 28*RxCLKIN). The UI scales with RxCLKIN frequency.
Note 7:
Supply noise testing was done with minimum capacitors on the PCB. A sinusoidal signal is AC coupled to the V
DDn
(1.8V) supply with amplitude = 100
mVp-p measured at the device V
DDn
pins. Bit error rate testing of input to the Ser and output of the Des with 10 meter cable shows no error when the noise
frequency on the Ser is less than 750 kHz. The Des on the other hand shows no error when the noise frequency is less than 400 kHz.
Note 8:
Specification is guaranteed by characterization and is not tested in production.
Note 9:
Specification is guaranteed by design and is not tested in production.
www.ti.com
8