L293D
QUADRUPLE HALF-H DRIVER
SLRS008A – SEPTEMBER 1986 – REVISED MAY 1990
schematics of inputs and outputs
EQUIVALENT OF EACH INPUT
TYPICAL OF ALL OUTPUTS
VCC2
VCC1
Current
Source
Input
Output
GND
GND
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Logic supply voltage range, V
CC1
(see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 V
Output supply voltage range, V
CC2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 V
Input voltage range, V
I
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Output voltage range, V
O
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 3 V to V
CC2
+ 3 V
Peak output current (nonrepetitive, t
≤
100
µs)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
±
1.2 A
Continuous output current, I
O
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
±
600 mA
Continuous total dissipation at (or below) 25°C free-air temperature (see Notes 2 and 3) . . . . . . . 2075 mW
Continuous total dissipation at 80°C case temperature (see Note 3) . . . . . . . . . . . . . . . . . . . . . . . . . 5000 mW
Operating case or virtual junction temperature range, T
J
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 40°C to 150°C
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
NOTES: 1. All voltage values are with respect to the network ground terminal.
2. For operation above 25°C free-air temperature, derate linearly at the rate of 16.6 mW/°C.
3. For operation above 25°C case temperature, derate linearly at the rate of 71.4 mW/°C. Due to variations in individual device electrical
characteristics and thermal resistance, the built-in thermal overload protection may be activated at power levels slightly above or
below the rated dissipation.
recommended operating conditions
MIN
Logic supply voltage, VCC1
Output supply voltage, VCC2
High-level
High level input voltage, VIH
voltage
Low-level input voltage, VIL
VCC1
≤
7 V
VCC1
≥
7 V
4.5
VCC1
2.3
2.3
– 0.3†
MAX
7
36
VCC1
7
1.5
UNIT
V
V
V
V
Operating free-air temperature, TA
0
70
°C
† The algebraic convention, in which the least positive (most negative) value is designated minimum, is used in this data sheet for logic voltage
levels.
3–2
POST OFFICE BOX 655303
•
DALLAS, TEXAS 75265