SLOS068R − JUNE 1976 − REVISED JULY 2010
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
LM158, LM158A
LM258, LM258A
LM358, LM358A
LM2904V
Supply voltage, V
CC
(see Note 1)
Differential input voltage, V
ID
(see Note 2)
Input voltage, V
I
(either input)
Duration of output short circuit (one amplifier) to ground
at (or below) 25°C free-air temperature (V
CC
15 V) (see Note 3)
D package
DGK package
Package thermal impedance,
q
JA
(see Notes 4 and 5)
P package
PS package
PW package
Package thermal impedance
q
JC
(see Notes 6 and 7)
impedance,
FK package
JG package
LM158, LM158A
LM258, LM258A
Operating free air temperature range T
A
free-air
range,
LM358, LM358A
LM2904
Operating virtual junction temperature, T
J
Case temperature for 60 seconds
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds
Storage temperature range, T
stg
LM2904
±13
or 26
±26
−0.3 to 26
Unlimited
97
172
85
95
149
UNIT
±16
or 32
±32
−0.3 to 32
Unlimited
97
172
85
95
149
5.61
14.5
−55 to 125
−25 to 85
0 to 70
−40 to 125
150
FK package
JG package
260
300
−65 to 150
V
V
V
°C/W
C/W
°C/W
°C
−40 to 125
150
300
−65 to 150
°C
°C
°C
°C
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values, except differential voltages and V
CC
specified for measurement of I
OS
, are with respect to the network ground
terminal.
2. Differential voltages are at IN+ with respect to IN−.
3. Short circuits from outputs to V
CC
can cause excessive heating and eventual destruction.
4. Maximum power dissipation is a function of T
J
(max),
q
JA
, and T
A
. The maximum allowable power dissipation at any allowable
ambient temperature is P
D
= (T
J
(max) − T
A
)/q
JA
. Operating at the absolute maximum T
J
of 150°C can affect reliability.
5. The package thermal impedance is calculated in accordance with JESD 51-7.
6. Maximum power dissipation is a function of T
J
(max),
q
JC
, and T
C
. The maximum allowable power dissipation at any allowable case
temperature is P
D
= (T
J
(max) − T
C
)/q
JC
. Operating at the absolute maximum T
J
of 150°C can affect reliability.
7. The package thermal impedance is calculated in accordance with MIL-STD-883.