SLLS567E − MAY 2003 − REVISED JANUARY 2004
MAX211
5 V MULTICHANNEL RS 232 LINE DRIVER/RECEIVER
WITH
±15
kV ESD PROTECTION
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
†
Supply voltage range, V
CC
(see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 V to 6 V
Positive charge pump voltage range, V+ (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . V
CC
− 0.3 V to 14 V
Negative charge pump voltage range, V− (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.3 V to −14 V
Input voltage range, V
I
: Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 V to V+ + 0.3 V
Receivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
±30
V
Output voltage range, V
O
: Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V− − 0.3 V to V+ + 0.3 V
Receivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 V to V
CC
+ 0.3 V
Short-circuit duration: DOUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Continuous
Package thermal impedance,
θ
JA
(see Notes 2 and 3): DB package . . . . . . . . . . . . . . . . . . . . . . . . . . . 62°C/W
DW package . . . . . . . . . . . . . . . . . . . . . . . . . . 46°C/W
Operating virtual junction temperature, T
J
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150°C
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltages are with respect to network GND.
2. Maximum power dissipation is a function of TJ(max),
θ
JA, and TA. The maximum allowable power dissipation at any allowable
ambient temperature is PD = (TJ(max) − TA)/
θ
JA. Operating at the absolute maximum TJ of 150°C can affect reliability.
3. The package thermal impedance is calculated in accordance with JESD 51-7.
recommended operating conditions (see Note 4 and Figure 4)
MIN
Supply voltage
Driver high-level input voltage
VIH
VIL
VI
TA
Control high-level input voltage
Driver and control low-level input voltage
Driver and control input voltage
Receiver input voltage
MAX211C
Operating free-air temperature
MAX211I
NOTE 4: Test conditions are C1−C4 = 0.1
µF
at VCC = 5 V
±
0.5 V.
DIN
EN, SHDN
DIN, EN, SHDN
DIN, EN, SHDN
0
−30
0
−40
4.5
2
2.4
0.8
5.5
30
70
85
V
°C
V
V
NOM
5
MAX
5.5
UNIT
V
electrical characteristics over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted) (see Note 4)
PARAMETER
ICC
Supply current
Shutdown supply current
No load,
TA = 25°C,
TEST CONDITIONS
See Figure 6
See Figure 1
MIN
TYP‡
14
1
MAX
20
10
UNIT
mA
µA
‡ All typical values are at VCC = 5 V, and TA = 25°C.
NOTE 4: Test conditions are C1−C4 = 0.1
µF
at VCC = 5 V
±
0.5 V.
4
POST OFFICE BOX 655303
•
DALLAS, TEXAS 75265