SCLS132E − DECEMBER 1982 − REVISED SEPTEMBER 2003
SN54HC251, SN74HC251
DATA SELECTORS/MULTIPLEXERS
WITH 3 STATE OUTPUTS
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
†
Supply voltage range, V
CC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V
Input clamp current, I
IK
(V
I
< 0 or V
I
> V
CC
) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
±20
mA
Output clamp current, I
OK
(V
O
< 0 or V
O
> V
CC
) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
±20
mA
Continuous output current, I
O
(V
O
= 0 to V
CC
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
±35
mA
Continuous current through V
CC
or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
±70
mA
Package thermal impedance,
θ
JA
(see Note 2): D package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73°C/W
DB package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82°C/W
N package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67°C/W
NS package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64°C/W
PW package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108°C/W
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
2. The package thermal impedance is calculated in accordance with JESD 51-7.
recommended operating conditions (see Note 3)
SN54HC251
MIN
VCC
VIH
Supply voltage
VCC = 2 V
VCC = 4.5 V
VCC = 6 V
VCC = 2 V
VIL
VI
VO
∆t/∆v
Low-level input voltage
Input voltage
Output voltage
VCC = 2 V
VCC = 4.5 V
VCC = 6 V
VCC = 4.5 V
VCC = 6 V
0
0
2
1.5
3.15
4.2
0.5
1.35
1.8
VCC
VCC
1000
500
400
0
0
NOM
5
MAX
6
SN74HC251
MIN
2
1.5
3.15
4.2
0.5
1.35
1.8
VCC
VCC
1000
500
400
ns
V
V
V
V
NOM
5
MAX
6
UNIT
V
High-level input voltage
Input transition rise/fall time
TA
Operating free-air temperature
−55
125
−40
85
°C
NOTE 3: All unused inputs of the device must be held at VCC or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs,
literature number SCBA004.
4
POST OFFICE BOX 655303
•
DALLAS, TEXAS 75265