SN54LV4053A, SN74LV4053A
TRIPLE 2 CHANNEL ANALOG MULTIPLEXERS/DEMULTIPLEXERS
SCLS430K − MAY 1999 − REVISED APRIL 2005
PARAMETER MEASUREMENT INFORMATION
VCC
VINH = VIH
VCC
VI
A
(OFF)
GND
VO
Condition 1: VI = 0, VO = VCC
Condition 2: VI = VCC, VO = 0
Figure 2. Off-State Switch Leakage-Current Test Circuit
VCC
VINH = VIL
VCC
VI
A
(ON)
GND
Open
VI = VCC or GND
Figure 3. On-State Switch Leakage-Current Test Circuit
VCC
VINH = VIL
VCC
Input
50
Ω
(ON)
GND
CL
Output
Figure 4. Propagation Delay Time, Signal Input to Signal Output
POST OFFICE BOX 655303
•
DALLAS, TEXAS 75265
7