Absolute Maximum Ratings
(1)
over operating junction temperature range (unless otherwise noted)
MIN
Continuous input voltage
Transient input voltage
(2)
Continuous reverse input voltage
Transient reverse input voltage
T
J
T
stg
(1)
(2)
Operating virtual junction temperature
Lead temperature
Storage temperature range
1,6 mm (1/16 in) for 10 s
–65
t
≤
100 ms
T
A
= 25°C
MAX
26
60
–15
–50
150
260
150
UNIT
V
V
V
V
°C
°C
°C
Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
The transient input voltage rating applies to the waveform shown in Figure 1.
Package Thermal Data
(1)
PACKAGE
PDIP (P)
PowerFLEX™ (KTE)
SOIC (D)
TO-226/TO-92 (LP)
TO-220 (KC)
TO-220 (KCS)
TO-252 (KVU)
TO-263 (KTT)
(1)
BOARD
High K, JESD 51-7
High K, JESD 51-5
High K, JESD 51-7
High K, JESD 51-7
High K, JESD 51-5
High K, JESD 51-5
High K, JESD 51-5
High K, JESD 51-5
θ
JC
57°C/W
3°C/W
39°C/W
55°C/W
3°C/W
3°C/W
–
18°C/W
θ
JA
85°C/W
23°C/W
97°C/W
140°C/W
19°C/W
19°C/W
30.3°C/W
25.3°C/W
Maximum power dissipation is a function of T
J
(max),
θ
JA
, and T
A
. The maximum allowable power dissipation at any allowable ambient
temperature is P
D
= (T
J
(max) – T
A
)/θ
JA
. Operating at the absolute maximum T
J
of 150°C can affect reliability.
Recommended Operating Conditions
over recommended operating junction temperature range (unless otherwise noted)
MIN
TL75xL05
V
I
Input voltage
TL75xL08
TL75xL10
TL75xL12
V
IH
V
IL (1)
I
O
T
J
(1)
High-level ENABLE input voltage
Low-level ENABLE input voltage
Output current
Operating virtual junction temperature
T
J
= 25°C
T
J
= 0°C to 125°C
TL75xLxx
TL75xLxx
TL75xLxx
TL75xLxx
TL75xLxxC
6
9
11
13
2
–0.3
–0.15
0
0
MAX
26
26
26
26
15
0.8
0.8
150
125
V
V
mA
°C
V
UNIT
The algebraic convention, in which the least positive (most negative) value is designated minimum, is used in this data sheet for
ENABLE voltage levels and temperature only.