TLC225x, TLC225xA
Advanced LinCMOS™ RAIL-TO-RAIL
VERY LOW-POWER OPERATIONAL AMPLIFIERS
SLOS176A – FEBRUARY 1997 – REVISED JULY 1999
electrical characteristics at specified free-air temperature, V
DD
= 5 V (unless otherwise noted)
PARAMETER
VIO
α
VIO
Input offset voltage
Temperature coefficient of input offset voltage
Input offset voltage long-term drift (see Note 4)
IIO
IIB
Input offset current
Input bias current
VIC = 0,
0,
VO = 0
VDD
±
=
±
2.5 V,
RS = 50
Ω
TEST CONDITIONS
TA†
25°C
Full range
25°C
to 70°C
25°C
25°C
Full range
25°C
Full range
25°C
VICR
Common mode input voltage range
Common-mode
RS = 50
Ω
Ω,
|V
IO
| ≤
5 mV
Full range
g
IOH = – 20
µA
VOH
High-level
High level output voltage
IOH = – 75
µA
IOH = – 150
µA
VIC = 2.5 V,
VIC = 2 5 V
2.5 V,
VOL
Low-level output voltage
VIC = 2 5 V
2.5 V,
VIC = 2 5 V
2.5 V,
25°C
25°C
Full range
25°C
IOL = 50
µA
IOL = 500
µA
IOL = 1
IOL = 4
25°C
25°C
Full range
25°C
Full range
25°C
Full range
25°C
Full range
25°C
25°C
25°C
f = 10 kHz,
f = 25 kHz,
VIC = 0 to 2.7 V,
,
RS = 50
Ω
P package
AV = 10
VO = 2.5 V,
,
25°C
25°C
25°C
Full range
25°C
Full range
25°C
Full range
70
70
80
80
70
125
150
95
100
10
1700
1012
1012
8
200
83
Ω
Ω
pF
Ω
dB
dB
µA
350
V/mV
0.7
0.2
4.9
4.8
4.8
4.88
0.01
0.09
0.15
0.15
0.3
0.3
1
1.2
V
0
to
4
0
to
3.5
4.98
4.94
V
– 0.3
to
4.2
1
100
0.5
05
0.003
0.5
100
TLC2252C
MIN
TYP
200
MAX
1500
1750
UNIT
µV
µV/°C
µV/mo
pA
pA
V
m
A
m
A
AVD
rid
ric
cic
zo
CMRR
kSVR
IDD
Large-signal differential voltage amplification
g
g
g
RL = 100 kه
VIC = 2.5 V,
25V
VO = 1 V to 4 V
RL = 1 Mه
Differential input resistance
Common-mode input resistance
Common-mode input capacitance
Closed-loop output impedance
Common-mode
Common mode rejection ratio
Supply-voltage
Supply voltage rejection ratio (∆VDD/∆VIO)
Supply current
VDD = 4.4 V to 16 V,
,
VIC = VDD /2,
No load
VO = 2 5 V
2.5 V,
No load
† Full range is 0°C to 70°C.
‡ Referenced to 2.5 V
NOTE 4: Typical values are based on the input offset voltage shift observed through 500 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
6
POST OFFICE BOX 655303
•
DALLAS, TEXAS 75265