SBVS147 – SEPTEMBER 2010
RECOMMENDED OPERATING CONDITIONS
TLC5960
PARAMETER
DC Characteristics
V
IN
V
D
V
IH
V
IL
I
SINK
C
LOAD
V
G
C
VREG5
T
A
T
J
t
WH0
/t
WL0
t
WH1
/t
WL1
t
SU0
t
H0
Supply voltage
Voltage applied to sense input (D1 to D8, S1 to S8)
High-level input voltage (CTRL1 to CTRL4)
Low-level input voltage (CTRL1 to CTRL4)
Low-level output current (XFLT)
Capacitive load of Gn outputs (G1 to G8)
MOSFET threshold voltage (G1 to G8)
Regulator output capacitor (VREG5)
Operating free-air temperature range
Operating junction temperature range
CTRLn pulse duration (CTRL1, 2, 3, 4 = high or low)
EN pulse duration (EN = high or low)
Setup time (EN to CTRL1, 2, 3, 4)
Hold time (EN to CTRL1, 2, 3, 4)
1.0
–40
–40
4
50
50
2
2.2
+85
+125
100
10
GND
1.2
GND
24
28
34
5.5
0.4
1
500
2.8
V
V
V
V
mA
pF
V
µF
°C
°C
µs
µs
µs
µs
MIN
NOM
MAX
UNIT
AC Characteristics: At VIN = 10V to 28V and T
A
= –40°C to +85°C
Copyright © 2010, Texas Instruments Incorporated
Product Folder Link(s):
3