ULQ2003A Q1, ULQ2004A Q1,
HIGH VOLTAGE HIGH CURRENT DARLINGTON
TRANSISTOR ARRAY
SGLS148B − DECEMBER 2002 − REVISED JUNE 2006
D
Qualification in Accordance With
D
D
D
D
D
D
D
D
AEC-Q100
†
Qualified for Automotive Applications
Customer-Specific Configuration Control
Can Be Supported Along With
Major-Change Approval
ESD Protection Exceeds 200 V Using
Machine Model (C = 200 pF, R = 0)
500-mA Rated Collector Current
(Single Output)
High-Voltage Outputs . . . 50 V
Output Clamp Diodes
Inputs Compatible With Various Types of
Logic
Relay-Driver Applications
1B
2B
3B
4B
5B
6B
7B
E
D PACKAGE
(TOP VIEW)
1
2
3
4
5
6
7
8
16
15
14
13
12
11
10
9
1C
2C
3C
4C
5C
6C
7C
COM
† Contact Texas Instruments for details. Q100 qualification data
available on request.
description
The ULQ2003A and ULQ2004A are high-voltage high-current Darlington transistor arrays. Each consists of
seven npn Darlington pairs that feature high-voltage outputs with common-cathode clamp diodes for switching
inductive loads. The collector-current rating of a single Darlington pair is 500 mA. The Darlington pairs can be
paralleled for higher current capability. Applications include relay drivers, hammer drivers, lamp drivers, display
drivers (LED and gas discharge), line drivers, and logic buffers.
The ULQ2003A has a 2.7-kΩ series base resistor for each Darlington pair, for operation directly with TTL or 5-V
CMOS devices. The ULQ2004A has a 10.5-kΩ series base resistor to allow operation directly from CMOS
devices that use supply voltages of 6 V to 15 V. The required input current of the ULQ2004A is below that of
the ULQ2003A.
AVAILABLE OPTIONS
D PACKAGES
{
TA
SMALL OUTLINE
ULQ2003ATDQ1
ULQ2003ATDRQ1
−40°C to 105°C
ULQ2004ATDQ1
}
ULQ2004ATDRQ1
ULQ2003AQDRQ1
−40°C to 125°C
† The D package is available taped and reeled. Add the suffix R to
device type (e.g., ULQ2003TDADRQ1).
‡ ULQ2004ATDQ1 is Product Preview only.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
Copyright
2006, Texas Instruments Incorporated
POST OFFICE BOX 655303
•
DALLAS, TEXAS 75265
1