XC6367/6368
Series
■ELECTRICAL CHARACTERISTICS (Continued)
XC6367A503MR, XC6368A503MR
VOUT=5.0V, FOSC=300kHz,Ta=25℃
PARAMETER
Output Voltage
SYMBOL
VOUT
VDD
CONDITIONS
MIN.
4875
2.0
10.0
-
-
-
-
TYP.
5.000 5.125
-
-
-
MAX. UNITS
V
V
V
Supply Voltage (* 1)
Maximum Input Voltage
Oscillation Start Voltage 1
Oscillation Start Voltage 2
Oscillation Hold Voltage
Supply Current 1
Supply Current 2
Stand-by Current
Oscillation Frequency
Maximum Duty Ratio
PFM Duty Ratio (* 3)
CE "High" Voltage
10.0
-
VIN
VST1
VST2
VHLD
IDD1
IDD2
ISTB
Tr: 2SD1628, IOUT=1.0mA
VOUT=CE : Apply voltage
Tr: 2SD1628, IOUT=1.0mA
VOUT=CE=setting output voltage x 0.95
VOUT=CE=setting output voltage + 0.5V
VOUT=setting output voltage x 0.95, CE=0V
Same as IDD1
0.9
0.8
0.7
280
38
0.5
345
92
35
-
0.20
29
19
-
V
V
V
μA
μA
μA
kHz
%
%
V
-
-
180
22
-
300
85
25
-
-
-
255
78
15
0.65
-
-
-
-
FOSC
MAXDTY Same as IDD1
PFMDTY
VCEH
IOUT=0mA
VOUT=setting output voltage x0.95
VOUT=setting output voltage x0.95
Same as IDD1, VEXT=VOUT-0.4V
Same as IDD1, VEXT=0.4V
CE "Low" Voltage
VCEL
-
V
EXT "High" ON Resistance
EXT "Low" ON Resistance
Efficiency (* 2)
REXTH
REXTL
EFFI
20
13
87
Ω
Ω
%
Connect RSS and CSS,
CE:0V→3.0V
Soft-Start Time
TSS
5
10
20
msec
(XC6367C/F and XC6368C/F series)
Conditions: Unless otherwise specified, connect VDD to VOUT; VIN=setting output voltage x 0.6, IOUT=200mA
NOTE:
* 1: When taking VDD from another power source please ensure that VDD = 2.0V or more.
Oscillation will occur with a value of VDD = 0.8V or more, but with a value of VDD = 2.0V or more,
output voltage and oscillation frequency will be stable.
* 2: EFFI = {[(output voltage) x (output current)]÷[(input voltage) x (input current)] x 100
* 3: Applies to the XC6368 series only (duty ratio when control changes to PFM).
* 4: The values of supply voltage and NOTE *1 do not apply to XC6367E/F and XC6368E/F series. For XC6367E/F and
XC6368E/F series, output voltage less than 2.0V cannot be set-up.
559