XC74WL4066SR
■ABSOLUTE
MAXIMUM RATINGS
PARAMETER
Supply Voltage
Input Voltage
Output Voltage
Input Diode Current
Output Diode Current
Switch Output Current
V
CC
,GND Current
Power Dissipation (Ta = 25℃)
Storage Temperature Range
Note : Voltage is all ground standardized.
Ta=-40℃~85℃
SYMBOL
V
CC
V
CONT
Vi/o
I
IK
I
OK
I
i/O
I
CC
,I
GND
Pd
Tstg
RATINGS
-0.5~+6.0
-0.5~+6.0
-0.5~V
CC
+0.5
-20
±20
±25
±50
300
-65~+150
UNITS
V
V
V
mA
mA
mA
mA
mW
℃
■RECOMMENDED
OPERATING CONDITIONS
PARAMETER
Supply Voltage
Input Voltage
Output Voltage
Operating Temperature Range
Input Rise and Fall Time
SYMBOL
V
CC
V
CONT
Vi/o
Topr
tr,tf
CONDITIONS
2~5.5
0~5.5
0~VCC
-40~+85
0~200(VCC=3.3V)
0~100(VCC=5V)
UNITS
V
V
V
℃
ns
■DC
ELECTRICAL CHARACTERISTICS
PARAMETER
High Level
Control Input Voltage
SYMBOL
V
CC
(V)
2.0
V
IH
3.0
5.5
Low Level
Control Input Voltage
2.0
V
IL
3.0
5.5
2.0
Peak ON Resistance
R
ONmax
3.0
4.5
2.0
ON Resistance
R
ON
(1)
3.0
4.5
Switch ON Resistance
Differential
Power Off Leak Current
Power On Leak Current
Control Input Current
Static Supply Current
2.0
△R
ON
I
S
(OFF)
I
S
(ON)
I
CONT
I
CC
3.0
4.5
5.5
5.5
0~5.5
5.5
V
CONT
=V
IH
V
IN
=
0~V
CC
I
IN/OUT
=
1mA
V
CONT
=V
IH
V
IN
=GND or V
CC
I
IN/OUT
=
1mA
V
CONT
=V
IH
V
IN
=0~V
CC
I
IN/OUT
=
1mA
V
CONT
=V
IL
, V
IN
=
V
CC,
V
OUT
=GND
V
CONT
=V
IH
, V
IN
=
V
CC, OR
GND
V
IN
=V
CC
or GND
V
IN
=V
CC
or GND
CONDITIONS
Ta=25℃
MIN.
1.50
2.10
3.85
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
TYP.
−
−
−
−
−
−
130
22
12
23
14
10
13
3
2
−
−
−
−
MAX.
−
−
−
0.50
0.90
1.65
350
50
25
50
30
20
35
6
4
±0.1
±0.1
±0.1
2.0
Ta=-40℃~85℃
MIN.
1.50
2.10
3.85
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
MAX.
−
−
−
0.50
0.90
1.65
550
65
35
65
40
25
55
8
6
±1.0
±1.0
±1.0
20.0
μA
μA
μA
μA
Ω
Ω
Ω
V
V
UNITS
2/11