欢迎访问ic37.com |
会员登录 免费注册
发布采购

RSFBL 参数 Datasheet PDF下载

RSFBL图片预览
型号: RSFBL
PDF下载: 下载PDF文件 查看货源
内容描述: 0.5 AMP 。表面安装快恢复二极管 [0.5 AMP. Surface Mount Fast Recovery Rectifiers]
分类和应用: 二极管快恢复二极管
文件页数/大小: 2 页 / 52 K
品牌: TSC [ TAIWAN SEMICONDUCTOR COMPANY, LTD ]
 浏览型号RSFBL的Datasheet PDF文件第2页  
RSFAL
THRU
RSFML
0.5 AMP. Surface Mount Fast Recovery Rectifiers
Voltage Range
50 to 1000 Volts
Current
0.5 Ampere
Features
For surface mounted application
Glass passivated junction chip
High temperature metallurgically bonded
construction
Plastic material used carries Underwriters
Laboratory Classification 94V-O
Fast switching for high efficiency
High temperature soldering:
260℃/ 10 seconds at terminals
0.075(1.9)
0.067(1.7)
Sub SMA
0.056(1.43)
0.114(2.9)
0.106(2.7)
0.007(0.17)
0.01(0.23)
0.048(1.23)
5
O
0.047(1.2)
0.031(0.8)
Mechanical Data
Cases: Sub SMA plastic case
Terminals: Solder plated
Polarity: Indicated by cathode band
Packing: 12mm tape per E1A STD
RS-481
Weight: 15mg
A
0.15(3.8)
0.134(3.4)
5
O
DETAIL "A", SCALE=20/1
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25℃ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
Symbol
RSF RSF RSF RSF RSF RSF RSF
Type Number
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Marking Code ( Note 4 )
Maximum Average Forward Rectified Current
O
See Fig. 1 @T
L
=55 C
Peak Forward Surge Current, 8.3 ms Single Half
Sine-wave Superimposed on Rated Load
(JEDEC method )
Max. Full Load Reverse Current, Full cycle
Average T
A
=55℃
Maximum Instantaneous Forward Voltage
@ 0.5A
Maximum DC Reverse Current @ T
A
=25℃
at Rated DC Blocking Voltage @ T
A
=125℃
Maximum Reverse Recovery Time ( Note 1 )
Typical Junction Capacitance ( Note 2 )
Typical Thermal Resistance (Note 3)
Operating Temperature Range
Storage Temperature Range
V
RRM
V
RMS
V
DC
I
(AV)
I
FSM
I
R
V
F
I
R
AL
50
35
50
BL
100
70
100
DL
200
200
GL
400
400
JL
600
600
KL
800
800
ML
1000
700
1000
(0.00~0.10)
0.00~0.004
Units
V
V
V
140
280
420
560
FALYM FBLYM FDLYM FGLYM FJLYM FKLYM FMLYM
0.5
10
30
1.3
5
50
150
250
4.0
150
32
-55 to +150
-55 to +150
500
A
A
uA
V
uA
uA
nS
pF
℃/W
℃/W
Trr
Cj
R
θ
JA
R
θ
JL
T
J
T
STG
Notes: 1. Reverse Recovery Test Conditions: I
F
=0.5A, I
R
=1.0A, I
RR
=0.25A
2. Measured at 1 MHz and Applied V
R
=4.0 Volts
3. Measured on P.C.Board with 0.2” x 0.2” (5mm x 5mm) Copper Pad Areas.
4. FALYM: F=0.5A, A=50V, L-Low Profile, Y-Year Code, M-Month Code.
- 384 -