MODULE FAMILY ELECTRICAL CHARACTERISTICS
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature,
unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate.
Absolute Maximum Ratings
Parameter
+In to –In voltage
PC to –In voltage
+Out to -Out
1.0 V
1.5 V
1.8 V
2.5 V
3.0 V
3.3 V
5V
10 V
12 V
15 V
24 V
28 V
48 V
Isolation voltage
In to out
In to base
Out to base
Operating Temperature
Storage Temperature
Pin soldering temperature
Mounting torque
-0.5 to 4.0
-0.5 to 4.0
-0.5 to 4.0
-0.5 to 6.0
-0.5 to 6.0
-0.5 to 12.0
-0.5 to 12.0
-0.5 to 30.0
-0.5 to 30.0
-0.5 to 25
-0.5 to 50.0
-0.5 to 48.0
-0.5 to 60.0
2,250
2,250
707
-55 to +100
-65 to +125
500 (260)
750 (390)
5 (0.57)
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
°C
°C
°F (°C)
°F (°C)
in-lbs (N-m)
Test voltage
Test voltage
Test voltage
M-Grade
M-Grade
<5 sec; wave solder
<7 sec; hand solder
6 each
Rating
-1.0 to +85
-0.3 to +6.0
Unit
Vdc
Vdc
Notes
Note:
Stresses in excess of the maximum ratings can cause permanent damage to the device. Operation of the device is not implied at these or any other conditions
in excess of those given in the specification. Exposure to absolute maximum ratings can adversely affect device reliability.
Input Specifications
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-on
Overvoltage turn-off
Recommended external
input capacitance
30.4
75.7
33.8
31.8
77.3
78.8
100
81.0
Min
36
Typ
48
Max
75
85
35.3
Unit
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
µF
See Figure 19
Notes
VI Brick / 48V Input DC-DC Converter Modules
vicorpower.com
Rev. 1.0
Page 2 of 21