欢迎访问ic37.com |
会员登录 免费注册
发布采购

V300A3V3C264A 参数 Datasheet PDF下载

V300A3V3C264A图片预览
型号: V300A3V3C264A
PDF下载: 下载PDF文件 查看货源
内容描述: 300Vin / 3.3V输出/ 264Watts DC -DC转换器模块 [300Vin / 3.3Vout / 264Watts DC-DC Converter Module]
分类和应用: 转换器电源电路
文件页数/大小: 8 页 / 207 K
品牌: VICOR [ VICOR CORPORATION ]
 浏览型号V300A3V3C264A的Datasheet PDF文件第1页浏览型号V300A3V3C264A的Datasheet PDF文件第3页浏览型号V300A3V3C264A的Datasheet PDF文件第4页浏览型号V300A3V3C264A的Datasheet PDF文件第5页浏览型号V300A3V3C264A的Datasheet PDF文件第6页浏览型号V300A3V3C264A的Datasheet PDF文件第7页浏览型号V300A3V3C264A的Datasheet PDF文件第8页  
ELECTRICAL CHARACTERISTICS  
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature,  
unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate.  
MODULE OPERATING SPECIFICATIONS  
Parameter  
Min  
Typ  
Max  
375  
Unit  
Vdc  
Vdc  
Vdc  
Vdc  
Watts  
%
Notes  
Operating input voltage  
Input surge withstand  
Output voltage setpoint  
Output OVP setpoint  
Output power  
180  
300  
400  
<100ms  
3.267  
4.14  
3.300  
4.30  
3.333  
4.46  
264  
Nominal input; full load; 25°C  
25°C; recycle input voltage to restart ( 1 minute off )  
At 100°C baseplate temperature  
Nominal input; 75% of full load; 25°C  
Efficiency  
79  
80  
MODULE INPUT SPECIFICATIONS  
Parameter  
Min  
Typ  
Max  
Unit  
Vdc  
Notes  
Undervoltage turn-on  
Undervoltage turn-off  
Overvoltage turn-off/on  
Dissipation, standby  
174.6  
152.8  
178.2  
147.4  
Vdc  
Vdc  
Not included  
No load  
5.6  
8.4  
Watts  
MODULE OUTPUT SPECIFICATIONS  
Parameter  
Min  
Typ  
±0.02  
±0.06  
±0.002  
60  
Max  
±0.20  
±0.20  
±0.005  
75  
Unit  
%
Notes  
Line regulation  
Low line to high line; full load  
No load to full load; nominal input  
Over operating temperature range  
Nominal input, full load; 25°C; 20MHz bandwidth  
Output voltage 95% of nominal  
Output voltage <250mV  
Load regulation  
%
Temperature regulation  
Ripple and noise, p-p  
Current limit  
% / °C  
mV  
81.6  
56  
92.0  
92  
112.0  
112  
Amps  
Amps  
%
Short circuit current  
Power sharing accuracy  
±2  
±5  
10 to 100% of full load  
Of nominal output voltage. For trimming below  
90% of nominal, a minimum load of 10% of  
maximum rated power may be required.  
Programming range  
10  
110  
%
Note: For important information relative to applications where the converter modules are subject to continuous dynamic loading,  
contact Vicor applications engineering at 800-927-9474.  
MODULE MECHANICAL SPECIFICATIONS  
Slotted baseplate (style 1) requires no designator.  
For threaded baseplate add a "2" to the end of the  
part number. For thru-hole add a "3".  
Baseplate  
Pin style  
Slotted (Style 1)  
Short (Style 1)  
For long pin configuration add “Lto the end of the  
part number. See page 7 for pin dimensions.  
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715  
V300A3V3C264A DC-DC Converter  
Rev. 5.2  
Page 2 of 8  
Set your site on VICOR at www.vicorpower.com