VI-AIM Connection Diagram, Typical Application
.01 µF (Two 4700 pF)
Y-Rated Capacitors
Universal
AC In
.01 µF Ceramic
F2
F1
L1
+In
+Out
+Out
Gate
In
Gate
Out
-In
+S
Trim
-S
Gate In
Parallel
Gate Out
N/C
VI-200/J00
Driver
Z1
.47 µF
Load
C out*
N/C
-Out
-Out
L2/N
.01 µF Ceramic
VI-AIM
.01 µF (Two 4700 pF)
Y-Rated Capacitors
* See Vicor's Applications Manual, page 12-2, Selecting Capacitors for AIM Modules.
Z1: MOV P/N 03040
Fuse 1: 6.3A/250V (IEC 5X20 mm) Buss GDB-6.3 or 7A/250V (3AG 1/4" x 1 1/4") Littlefuse 314-007
Fuse 2: For VI-X7X-XX — Buss PC-Tron 2.5A (250V)
For VI-X6X-XX — Buss PC-Tron 3A (250V)
For VI-X5X-XX — Buss PC-Tron 5A
VI-AIM Block Diagram
+OUT
L1
C2
D2
D1
Q1
Gate Out
10V
Vref 1
U2
Parallel
Gate In
EMI
Filter
OV
Vref
2
Level
Shift
OC
Q2
U1
-OUT
L2/N
Mechanical Diagram
2.28
(57,9)
1.30
.49
(12,4)
.080 Dia (2) places
Solder plate
over copper alloy
(33,0)
.65
(16,5)
.30±.015
(7,6)±(0,38)
Pin #
Function
L1
1
2
3
4
5
6
7
8
9
4
3
9
NC
NC
L2/N
8
7
6
2.10
(53,4)
1.40
VI-AIM
(35,6)
1.00
(25,4)
+Out
.70
(17,8)
2
1
.40
(10,2)
Gate In
Parallel
Gate Out
–Out
5
.35± .015
(8,9)±(0,38)
FULL R
.15
(3,8)
.040 (1,0) Dia (7) places
Solder plate
over copper alloy
.15
(3,8)
Product ID
this surface
2.40
(61,0)
1.90
(48,3)
.22
(5,6) Min.
1.75 Max.
(44,4)
.30 Min.
(7,6)
+.030
(0,76)
.50
(12,7)
-.000
(0)
.01
.12
(3,0)
Aluminum Base
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
AIM, Universal AC Input Front End Module P/N 21924
Rev. 2.2 1/05/10M
Set your site on VICOR at www.vicorpower.com