DG441/442
Vishay Siliconix
SPECIFICATIONS
a
FOR SINGLE SUPPLY
Test Conditions
Unless Otherwise Specified
V+ = 12 V, V- = 0 V
Parameter
Analog Switch
Analog Signal Range
e
Drain-Source
On-Resistance
Dynamic Characteristics
Turn-On Time
Turn-Off Time
Charge Injection
Power Supplies
Positive Supply Current
Negative Supply Current
Ground Current
Notes:
a. Refer to PROCESS OPTION FLOWCHART.
b. Room = 25 °C, Full = as determined by the operating temperature suffix.
c. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
e. Guaranteed by design, not subject to production test.
f. V
IN
= input voltage to perform proper function.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
A Suffix
- 55 to 125 °C
Temp
b
Full
Typ
c
Min
d
0
100
Max
d
12
160
200
450
200
D Suffix
- 40 to 85 °C
Min
d
0
Max
d
12
160
200
450
200
ns
pC
Unit
V
Ω
Symbol
V
ANALOG
r
DS(on)
V
IN
= 2.4 V, 0.8 V
f
I
S
= - 10 mA, V
D
=
3
V, 8 V
V+ = 10.8 V
R
L
= 1 kΩ, C
L
= 35 pF
V
S
=
8
V
See Figure 2
C
L
= 1nF, V
gen
= 6 V, R
gen
= 0
Ω
Room
Full
Room
Room
Room
Full
Room
Full
Full
t
ON
t
OFF
Q
I+
I-
I
GND
300
60
2
15
- 0.0001
- 15
100
-1
- 100
- 100
-1
- 100
- 100
100
µA
V+ = 13.2 V, V- = 0 V
V
IN
= 0 or 5 V
www.vishay.com
4
Document Number: 70053
S-71241–Rev. I, 25-Jun-07