欢迎访问ic37.com |
会员登录 免费注册
发布采购

H11C5 参数 Datasheet PDF下载

H11C5图片预览
型号: H11C5
PDF下载: 下载PDF文件 查看货源
内容描述: 光电耦合器, PhotoSCR输出, 400 V VRM , 5 A浪涌电流 [Optocoupler, PhotoSCR Output, 400 V VRM, 5 A surge current]
分类和应用: 光电输出元件
文件页数/大小: 5 页 / 96 K
品牌: VISHAY [ VISHAY TELEFUNKEN ]
 浏览型号H11C5的Datasheet PDF文件第2页浏览型号H11C5的Datasheet PDF文件第3页浏览型号H11C5的Datasheet PDF文件第4页浏览型号H11C5的Datasheet PDF文件第5页  
H11C4/ H11C5/ H11C6
Vishay Semiconductors
Optocoupler, PhotoSCR Output, 400 V V
RM
, 5 A surge current
Features
Turn on current (I
FT
), 5.0 mA typical
Gate trigger current (I
GT
), 20 mA typical
Surge anode current, 5.0 A
Blocking voltage, 400 V gate trigger voltage (V
GT
),
0.6 V typical
Isolation test voltage 5300 V
RMS
Solid State reliability
Lead-free component
Component in accordance to RoHS 2002/95/EC
and WEEE 2002/96/EC
A 1
C 2
NC 3
6 G
5 A
4 C
i179006
e3
Pb
Pb-free
Agency Approvals
• UL1577, File No. E52744 System Code H or J,
Double Protection
Order Information
Part
H11C4
H11C5
H11C6
H11C4-X006
H11C6-X009
Remarks
I
FT
11 mA, DIP-6
I
FT
11 mA, DIP-6
I
FT
14 mA, DIP-6
I
FT
11 mA, DIP-6 400 mil (option 6)
I
FT
14 mA, SMD-6 (option 9)
Description
The H11C4/ H11C5/ H11C6 are optically coupled
SCRs with a gallium arsenide infrared emitter and a
silicon photo SCR sensor. Switching can be achieved
while maintaining a high degree of isolation between
triggering and load circuits. These optocouplers can
be used in SCR triac and solid state relay applications
where high blocking voltages and low input current
sensitivity are required.
The H11C4 and H11C5 are identical and have a max-
imum turn-on-current of 11 mA. The H11C6 has a
maximum of 14 mA.
For additional information on the available options refer to
Option Information.
Absolute Maximum Ratings
T
amb
= 25 °C, unless otherwise specified
Stresses in excess of the absolute Maximum Ratings can cause permanent damage to the device. Functional operation of the device is
not implied at these or any other conditions in excess of those given in the operational sections of this document. Exposure to absolute
Maximum Rating for extended periods of the time can adversely affect reliability.
Input
Parameter
Peak reverse voltage
Forward continuous current
Peak forward current
Power dissipation
Derate linearly from 25 °C
1.0 ms, 1 % Duty Cycle
Test condition
Symbol
V
RM
I
F
I
FM
P
diss
Value
6.0
60
3.0
100
1.33
Unit
V
mA
A
mW
mW/°C
Document Number 83610