欢迎访问ic37.com |
会员登录 免费注册
发布采购

CG24S51-5000-RC 参数 Datasheet PDF下载

CG24S51-5000-RC图片预览
型号: CG24S51-5000-RC
PDF下载: 下载PDF文件 查看货源
内容描述: [DC-DC Regulated Power Supply Module,]
分类和应用:
文件页数/大小: 9 页 / 410 K
品牌: WALL [ WALL INDUSTRIES,INC. ]
 浏览型号CG24S51-5000-RC的Datasheet PDF文件第1页浏览型号CG24S51-5000-RC的Datasheet PDF文件第2页浏览型号CG24S51-5000-RC的Datasheet PDF文件第3页浏览型号CG24S51-5000-RC的Datasheet PDF文件第4页浏览型号CG24S51-5000-RC的Datasheet PDF文件第5页浏览型号CG24S51-5000-RC的Datasheet PDF文件第7页浏览型号CG24S51-5000-RC的Datasheet PDF文件第8页浏览型号CG24S51-5000-RC的Datasheet PDF文件第9页  
Rev B
Single Output
2:1 Input Voltage Range
30 Watt DC/DC Converter
CG Series
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source
impedances can affect the stability of the power module.
In applications where power is supplied over long lines and output loading is high, it may be necessary
to use a capacitor at the input to ensure startup.
A capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to
use a good quality low Equivalent Series Resistance (ESR < 1.0Ω
at 100 KHz) capacitor of 10uF for the
24V and 48V input devices.
Maximum Capacitive Load
The CG Series has a limitation of maximum connected capacitance at the output. The power module
may be operated in current limiting mode during start-up, affecting the ramp-up and the startup time.
The maximum capacitance can be found in the “Output Voltage / Current Rating Chart.”
Over Current Protection
To provide protection in a fault (output overload) condition, the unit is equipped with internal current
limiting circuitry and can endure current limiting for an unlimited duration. At the point of current-limit
inception, the unit shifts from voltage control to current control. The unit operates normally once the
output current is brought back into its specified range.
Output Over Voltage Protection
The output over voltage clamp consists of control circuitry, which is independent of the primary
regulation loop that monitors the voltage on the output terminals. The control loop of the clamp has a
higher voltage set point than the primary loop. This provides a redundant voltage control that reduces
the risk of output over voltage. The OVP level can be found in the “Output Voltage / Current Rating
Chart.”
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over
the module, and board spacing. To avoid exceeding the maximum temperature rating of the components
inside the power module, the case temperature must be kept below 105°C. The derating curves are
determined from measurements obtained in an experimental apparatus.
5/15/2019
Wall Industries, Inc. • Tel: 603-778-2300 • Toll Free: 888-597-9255 •
website:
• e-mail:
Page 6 of 9