欢迎访问ic37.com |
会员登录 免费注册
发布采购

SIG60 参数 Datasheet PDF下载

SIG60图片预览
型号: SIG60
PDF下载: 下载PDF文件 查看货源
内容描述: UART电力线的AC / DC- BUS网络 [UART over Powerline for AC/DC-BUS Network]
分类和应用:
文件页数/大小: 14 页 / 554 K
品牌: YAMAR [ YAMAR ELECTRONICS LTD. ]
 浏览型号SIG60的Datasheet PDF文件第5页浏览型号SIG60的Datasheet PDF文件第6页浏览型号SIG60的Datasheet PDF文件第7页浏览型号SIG60的Datasheet PDF文件第8页浏览型号SIG60的Datasheet PDF文件第10页浏览型号SIG60的Datasheet PDF文件第11页浏览型号SIG60的Datasheet PDF文件第12页浏览型号SIG60的Datasheet PDF文件第13页  
Preliminary and proprietary Information of YAMAR Electronics Ltd. Subject to change without notice.
Bit 5 -
nAuto WUM
- “1” disables the SIG60 from sending a Wake Up Message when wakened by its
host.
Bit 6-
nLoopBack
– “1” disables loopback of HDI to HDO.
Bit 7 -
Interference
– “1” when interference signal is detected on the AC/DC-BUS (Read Only).
Control Register 1
Bit 7
1
Reserved
Bit 6
1
Reserved
Bit 5
Bit 4
1
1
Bit Rate (table 4.3)
Bit 3
1
Bit 2
Bit 1
1
1
Frequency select (table 4.2)
Bit 0
1
Bit 0-3 –
Frequencies
- Selecting pair of operating frequencies see table 4.3.
Bit 4-5 –
Bit rate
- Selecting operating bit rate.
4.3
SIG60 Configuration
The SIG60 operates at default with the following parameters:
Bit rate: 19.2 kbps, F0=5.5MHz, F1=6.5MHz
The following configuration bits set the operating frequencies according to table 4.2.
Table 4.2 – F0, F1 select
Control_register1
(3:0)
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
F0
1.75Mhz
1.75Mhz
1.75Mhz
1.75Mhz
4.5Mhz
4.5Mhz
4.5Mhz
4.5Mhz
10.5Mhz
5.5Mhz
5.5Mhz
6.0Mhz
6.0Mhz
6.5Mhz
6.5Mhz
5.5Mhz
F1
4.5Mhz
5.5Mhz
6Mhz
6.5Mhz
5.5Mhz
6.0Mhz
6.5Mhz
10.5Mhz
13.0Mhz
10.5Mhz
13.0Mhz
10.5Mhz
13.0Mhz
10.5Mhz
13.0Mhz
6.5Mhz
Table 4.3 – bit rates selection
Bit Rates
Control_register1
00
01
10
11
(5:4)
1.75 MHz
4.50 MHz
5.50 MHz
6.00 MHz
6.50 MHz
10.50 MHz
13.00 MHz
-
38.4K
38.4K
38.4K
38.4K
38.4K
38.4K
-
57.6K
57.6K
57.6K
57.6K
57.6K
57.6K
9.6K
9.6K
9.6K
9.6K
9.6K
115.2
115.2
19.2K
19.2K
19.2K
19.2K
19.2K
19.2K
19.2K
4.3.1
Command Mode
When in command mode, the host can configure the device according to the desired operating
parameters. The device enters command mode when pin HDC is lowered to “0”. When in command
mode, data on the HDI pin is not transmitted to the bus, but is used to configure the SIG60. The
command can be written in any of the allowed Bit Rates.
In order to write to a control register, the host sends two bytes. The first byte begins with the address of
the register followed by 5(hex). The second byte is the configuration data, as shown in figure 4.1. The
bytes should be sent more than 200nSec after lowering HDC.
© 2010 Yamar Electronics Ltd.
9
DS-SIG60 R0.921