ZLNB2012
ELECTRICAL CHARACTERISTICS TEST CONDITIONS (Unless otherwise stated):
T
amb= 25 C,VCC
=5V
SYMBOL
PARAMETER
CONDITIONS
Min
TD 1,2 Outputs
V
VHIGH
V
VLOW
Voltage high
Voltage Low
BTD 1,2 Outputs
V
VHIGH
V
VLOW
Voltage high
Voltage Low
IBTD 1,2=-100 A, Test Circuit 1,
Tone disabled
IBTD 1,2=15mA, Test Circuit 1,
Tone enabled
V
CC
-1.0 V
CC
-0.7
0
0.3
V
CC
0.5
V
V
ITD 1,2=-100 A, Test Circuit 1,
Tone enabled
ITD 1,2=15mA, Test Circuit 1,
Tone disabled
V
CC
-1.0 V
CC
-0.7
0
0.3
V
CC
0.5
V
V
LIMITS
Typ
Max
UNITS
Note:-
1) The parameters Filter Amplifier V
OUT
, I
OUT
, Rectifier V
OUT
and Comparator Threshold Voltage are all directly (linearly)
related to Vcc.
2) Applied via 1k resistors
3) These parameters are linear related to V
CC
PROVISIONAL ISSUE A - OCTOBER 2001
3