欢迎访问ic37.com |
会员登录 免费注册
发布采购

Z0221524AEGR50A5 参数 Datasheet PDF下载

Z0221524AEGR50A5图片预览
型号: Z0221524AEGR50A5
PDF下载: 下载PDF文件 查看货源
内容描述: 单芯片调制解调器,集成控制器,数据泵和模拟前端 [Single Chip Modem with Integrated Controller, Data Pump, and Analog Front End]
分类和应用: 调制解调器控制器
文件页数/大小: 74 页 / 663 K
品牌: ZILOG [ ZILOG, INC. ]
 浏览型号Z0221524AEGR50A5的Datasheet PDF文件第17页浏览型号Z0221524AEGR50A5的Datasheet PDF文件第18页浏览型号Z0221524AEGR50A5的Datasheet PDF文件第19页浏览型号Z0221524AEGR50A5的Datasheet PDF文件第20页浏览型号Z0221524AEGR50A5的Datasheet PDF文件第22页浏览型号Z0221524AEGR50A5的Datasheet PDF文件第23页浏览型号Z0221524AEGR50A5的Datasheet PDF文件第24页浏览型号Z0221524AEGR50A5的Datasheet PDF文件第25页  
Z02215
Single Chip Modem with Integrated Controller, Data Pump, and AFE
15
Command Line Execution
The characters in a command line are executed one at a time. Any unexpected
characters (except control characters) stop command line execution and return an
ERROR
result code. Unexpected characters include numbers outside the range of
values accepted by the command. All control characters in a command line
except
Ctrl-X
(and the special characters such as <
CR
> and <
BS
>) are ignored.
The numerical argument of a command is assumed to be
0
if it is not provided.
For example, the commands
ATH
<
CR
> and
ATH0
<
CR
> both hang up the telephone
line.
When the modem has executed a command line, the result code of the most
recent command executed is returned to the terminal.
If the value written to a modem S-register is outside the range of values accepted
by the S-register, then its value is set to the nearest allowed value.
Leading
0
s in numeric arguments, including S-register numbers, are ignored. For
example, both set S-register S1 to 2
:
ATS1=2
ATS01=2
All numeric arguments, including S-register numbers, are decimal (base 10).
AT Command Prefix
Each modem command line begins with the letters
A
and
T
. The modem uses
these characters to determine the data rate and parity from the terminal.
A/ Repeat Last Command
To repeat the commands in the most recent command line, type the letters
A
and /
instead of
A
and
T
.
<CR> End-of-Line Character
This character is typed to end a command line. The value of the <
CR
> character is
stored in S-register S3. The default value is
13
(the ASCII carriage return charac-
ter).
When the <
CR
> character is entered, the modem executes the commands in the
command line.
PS001907-0904
AT Command Set