 浏览型号Z0221524AEGR50A5的Datasheet PDF文件第47页浏览型号Z0221524AEGR50A5的Datasheet PDF文件第48页浏览型号Z0221524AEGR50A5的Datasheet PDF文件第49页浏览型号Z0221524AEGR50A5的Datasheet PDF文件第50页浏览型号Z0221524AEGR50A5的Datasheet PDF文件第52页浏览型号Z0221524AEGR50A5的Datasheet PDF文件第53页浏览型号Z0221524AEGR50A5的Datasheet PDF文件第54页浏览型号Z0221524AEGR50A5的Datasheet PDF文件第55页  
Z02215
Single Chip Modem with Integrated Controller, Data Pump, and AFE
45
Alternatively, the user can select the \
R1
command option and use the
RTS
hard-
ware signal to initiate a line reversal. When
RTS
changes from active (logic
0
or 0
volts) to inactive (logic
1
or +5 volts), the line turnaround executes. This method is
the fastest method of executing the line turnaround.
At execution of the
R
command, the
Carrier Detect
signal (
CD
) goes inactive, the
modem reverses (its carrier changes from 390 Hz to 1300 Hz), and waits for a 390
Hz carrier for 440 ms.
If the modem detects more than 40 ms of a 390 Hz carrier within 440 ms, it
sends the
CONNECT 1200
/
75
result code to the Host. CD goes active.
If the modem does not detect more than 40 ms of a 390 Hz carrier within 440
ms, it hangs up and sends the
NO CARRIER
code to the Host.
Reverse Turnaround
The modem performs a Reverse turnaround when a carrier drop longer than 20
ms is detected. The
Carrier Detect
(
CD
) signal goes inactive and the modem
reverses its carrier (from 1300 Hz to 390 Hz) and waits for a 1300 Hz carrier for
220 ms.
If the modem detects more than 40 ms of a 1300 Hz carrier within 220 ms, it
sends the
CONNECT 75
/
1200
code to the Host. The CD then goes active.
If the modem does not detect more than 40 ms of a 1300 Hz carrier within 220
ms, it reverses again and waits for a 390 Hz carrier for 220 ms.
If the modem detects more than 40 ms of a 390 Hz carrier within 220 ms, it
sends the
CONNECT 1200
/
75
code to the Host. The
CD
then goes active
(there was a short carrier dropout).
If the modem does not detect more than 40 ms of a 390 Hz carrier within
220 ms, it hangs up and sends the
NO CARRIER
code to the Host.
If the modem is in REVERSE mode and receives the R command, it sends the
ERROR
code to the Host.
STATIC REVERSE Mode
If the command ATR has been executed, the following ATD command forces the
modem to try to connect in REVERSE mode.
Escape Sequences
An escape sequence is one or more particular characters sent from the terminal to
the modem during the ON-LINE state. This sequence is activated to switch the
PS001907-0904
Escape Sequences