ZiLOG
2002 Quality and Reliability Report
CHAPTER 3
Qualification Requirements
PRODUCT/PROCESS QUALIFICATION REQUIREMENTS
Per Procedures SOP0940, SOP0903 and SOP0909, ZiLOG performs initial qualification on new
processes, products and packages. Re-qualification is required when material changes occur.
Table 4-1. Product/Process Qualification Requirements
Sample
Size
Acceptance MIL-STD
Test
Test Conditions
Criteria
883C/Procedure
ESD
10
6
HBM
3015.7
2 KV Min.
CMOS Latchup
200 mA Min QR - QCC-1425
EIA/JESD78
3 PTIC, 3 NTIC
Operating Life
Temp Cycle
77
45
1/77
0/45
1005
150°C, 5V
184 Hour/Full Qual
1010, Condition C
–65°C to 150°C
500 Cycles/Qual
1000 Cycles/Test
Pressure Pot
HAST
45
45
0/45
0/45
QCC-1403
PM 25-13
336 Hours
121°C at 2 ATM
96 Hours
140° C, 85% RH,
2 ATM
Package Integrity
10
0/10
240°C, 10 Sec
Note: Process Qual requires three (3) lots, Product Qual requires one (1) lot.
ZAC03-0004
3- 1