产品型号C901U222MYVDBA7317的Datasheet PDF文件预览

Radial Leaded Ceramic Disc Capacitors  
Safety Standard Recognized, C900, Encapsulated,  
AC Type, X1 400 VAC/Y2 250 VAC (Industrial Grade)  
Overview  
KEMET’s 900 encapsulated radial leaded ceramic disc  
capacitors are specifically designed for interference-sup-  
pression AC line filtering applications. Having internation-  
ally recognized safety certifications, these capacitors are  
well-suited for applications that require keeping potentially  
disruptive or damaging line transients and EMI out of sus-  
ceptible equipment. They are also an ideal solution when  
needing to suppress line disturbances at the source.  
With a working voltage of 400 VAC in line-to-line (Class X)  
and 250 VAC in line-to-ground (Class Y) applications, these  
safety capacitors meet the impulse test criteria outlined in  
IEC Standard 60384. Meeting subclass X1 and Y2 require-  
ments, these devices are certified to withstand impulses up  
to 4 KV (X1) and 5 KV (Y2) respectively. These encapsulated  
devices also meet the flame test requirements outlined in UL  
Standard 94V–0.  
Safety Certified Capacitors are classified as either X and/  
or Y capacitors. Class X capacitors are primarily used in  
line-to-line (across-the-line) applications. In this applica-  
tion, there is no danger of electric shock to humans should  
the capacitor fail, but could result in a risk of fire. The class  
Y capacitor is primarily used in line-to-ground (line by-pass)  
applications. In this application, failure of the capacitor  
could lead to danger of electric shock.  
Click image above for interactive 3D content  
Open PDF in Adobe Reader for full functionality  
Ordering Information  
C9  
8
1
U
103  
M
Y
V
D
A
A
7317  
Ceramic  
Series  
Body  
Diameter  
Lead  
Spacing1,2,4  
Capacitance Capacitance  
Rated Dielectric/  
Voltage Temp. Char.  
Lead  
Config.1,3,4  
Failure Packaging  
Spec.  
Design  
Code (pF)  
Tolerance  
Rate  
(C-Spec)  
C9 =  
0 = 7.0 mm  
5 = 5.0 mm  
7 = 7.5 mm  
1 = 10.0 mm  
U =  
Safety  
Two  
J = ±5%  
Y =  
X1 400 Y = Y5P  
VAC/ W = Y5U  
Y2 250 V = Y5V  
VAC  
S = SL  
D = A = Straight  
Disc B = Vertical  
Kink  
A =  
See  
Ceramic 1 = 8.0 mm  
900  
significant K = ±10%  
digits and M = ±20%  
number of  
N/A "Packaging  
C-Spec  
2 = 9.0 mm  
3 = 10.0 mm  
4 = 11.0 mm  
6 = 13.0 mm  
8 = 15.0 mm  
C = Outside  
Kink  
D = Inside  
Kink  
Ordering  
Options  
Table"  
zeroes  
below  
1 Due to a high risk of arcing, "Inside Kink" lead configuration cannot be combined with the 5 mm lead spacing option. The "Inside Kink" option is only  
available on capacitors with lead spacing of 7.5 mm or greater. A potential for arcing may exist when combining the "Inside Kink" lead configuration  
with a 7.5 mm lead spacing option, especially in high humidity environments and/or when exposure to voltages and transients may impact creepage  
and clearance requirements.  
2 Capacitor body diameter will limit available lead spacing and packaging options. See "Dimensions" and "Product Ordering Codes and Ratings" sections  
of this document to determine availability.  
3 "Vertical Kink", "Outside Kink" and "Inside Kink" lead configurations cannot be combined with the bulk/20 mm lead length option (WL20). 20 mm lead  
length is only available on capacitors with straight leads (lead configuration ordering code "A"). For nonstandard lead length inquiries, please contact  
KEMET.  
4 Bulk packaging lead length availability is dependent upon "Lead Configuration" and "Lead Spacing." See "Dimensions" section of this document to  
verify availability of a specific lead length option. For nonstandard lead length inquiries, please contact KEMET.  
One world. One KEMET  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
C1064_X1_400 VAC_Y2_250 VAC • 8/4/2017  
1
Radial Leaded Ceramic Disc Capacitors  
Safety Standard Recognized, C900, Encapsulated, AC Type, X1 400 VAC/Y2 250 VAC (Industrial Grade)  
Packaging C-Spec Ordering Options Table  
Lead Length  
(mm)2,3  
Packaging  
Ordering Code (C-Spec)  
Packaging Type  
20.0 +1.5/−1.0 (straight leads)  
18.0 +2.0/−0 (preformed leads1)  
Ammo Pack  
7317  
3.0 ±1.0  
3.5 ±1.0  
WL30  
WL35  
WL40  
WL45  
WL50  
WL20  
4.0 ±1.0  
Bulk Bag  
4.5 ±1.0  
5.0 ±1.0  
20.0 minimum4  
1 Preformed (crimped) lead configurations include "Vertical Kink", "Outside Kink" and "Inside Kink". See "Lead Configurations" and "Ordering  
Information" sections of this document for further details.  
2 "Vertical Kink", "Outside Kink" and "Inside Kink" lead configurations cannot be combined with the bulk/20 mm lead length option (WL20). 20 mm lead  
length is only available on capacitors with straight leads (lead configuration ordering code "A"). For nonstandard lead length inquiries, please contact  
KEMET.  
3 For nonstandard lead length inquiries, please contact KEMET.  
4 Lead length of 20.0 mm minimum only available for straight leads.  
Benefits  
• Safety standard recognized (IEC 60384–14)  
• Reliable operation up to 125°C  
• Class X1/Y2  
• 5.0 mm, 7.5 mm, and 10 mm lead spacing  
• Lead (Pb)-free and RoHS Compliant  
• Halogen-free  
• Capacitance offerings ranging from 10 pF up to 10 nF  
• Available capacitance tolerances of ±5%, ±10%, and ±20%  
• High reliability  
• Preformed (crimped) or straight lead configurations  
• Non-polar device, minimizing installation concerns  
• Encapsulation meets flammability standard UL 94V–0  
Applications  
Typical applications include:  
• Line-to-line (Class X) filtering  
• Line-to-ground (Class Y) filtering  
• Antenna coupling  
• Primary and secondary coupling (switching power supplies)  
• Line disturbances suppression (motors and motor controls, relays, switching power supplies, and inverters)  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
C1064_X1_400 VAC_Y2_250 VAC • 8/4/2017  
2
Radial Leaded Ceramic Disc Capacitors  
Safety Standard Recognized, C900, Encapsulated, AC Type, X1 400 VAC/Y2 250 VAC (Industrial Grade)  
Lead Configurations  
Straight  
Vertical Kink  
Outside Kink  
Inside Kink1  
D
T
D
T
D
T
D
T
ꢁꢂ0  
ꢃaꢄimum  
ꢄꢁ0  
ꢂaꢃimum  
ꢄꢁ0  
ꢂaꢃimum  
ꢄꢁ0  
ꢂaꢃimum  
5ꢁ0 ꢂaꢃimum  
4ꢁ0 ꢂaꢃimum  
5ꢁ0 ꢂaꢃimum  
LL  
LL  
LL  
LL  
S
S
S
S
1 Due to a high risk of arcing, the "Inside Kink" lead configuration option cannot me combined with 5 mm lead spacing ("S" dimension above). The "Inside  
Kink" option is only available on devices with lead spacing of 7.5 mm or 10 mm.  
Dimensions – Millimeters  
S
D
T
e
ØF  
Lead  
Lead  
Spacing  
Tolerance  
Lead  
Configuration  
Configuration  
Lead  
Body  
Body  
Thickness  
Lead  
Meniscus  
Lead  
Diameter  
Ordering Code1  
Spacing2  
Diameter2  
5.0  
7.5  
±0.8  
±1.0  
±1.0  
±0.8  
±1.0  
±1.0  
±0.8  
±1.0  
±1.0  
±1.0  
±1.0  
Straight  
A
B
10.0  
5.0  
Vertical Kink  
(Preformed)  
7.5  
See Table 1 –  
"Product Ordering Codes  
and Ratings"  
3.0  
maximum  
10.0  
5.0  
0.55 ±0.1  
Outside Kink  
(Preformed)  
C
7.5  
10.0  
7.5  
Inside Kink  
(Preformed)  
D
10.0  
1 Lead Configuration is identified in the 13th character of the ordering code. See "Lead Configuration" and "Ordering Information" sections of this  
document for further details.  
2 Body diameter of capacitor will limit available lead spacing and packaging options. See "Product Ordering Codes and Ratings" sections of this  
document for further details.  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
C1064_X1_400 VAC_Y2_250 VAC • 8/4/2017  
3
Radial Leaded Ceramic Disc Capacitors  
Safety Standard Recognized, C900, Encapsulated, AC Type, X1 400 VAC/Y2 250 VAC (Industrial Grade)  
Approval Standard and Certification No.  
Safety Standard  
Standard No.  
Subclass  
Working Voltage  
400 VAC  
Certificate No.  
X1  
Y2  
X1  
Y2  
VDE  
(ENEC)  
IEC 60384–14  
40036415  
250 VAC  
400VAC  
UL  
CAN/CSA  
UL 60384–14 and  
E356389  
E60384–14  
250VAC  
These devices are VDE/ENEC and UL recognized for antenna coupling and AC line-to-line (class X) and line-to-ground (class Y) applications per  
IEC60384–14 and UL 60384–14.  
Environmental Compliance  
These devices are Halogen free and RoHS Compliant. They meet all requirements set forth by both EU and China RoHS  
directives.  
General Specifications/Performance Characteristics  
Dielectric/Temperature Characteristic  
SL  
Y5P  
Y5U  
Y5V  
Operating Temperature Range:  
−40°C to +125°C  
Capacitance Change with Reference to  
+25°C and 0 VDC Applied (TCC):  
−1,000 ~ +350 ppm/°C  
±10%  
+20%/−55%  
~ +30%/−80%  
Dielectric Withstanding Voltage (7.5 mm and 10 mm  
Lead Spacing)1  
2,600 VAC  
(60±5 seconds at 25°C)  
Dielectric Withstanding Voltage (5 mm Lead  
Spacing)1  
2,000 VAC  
(60±5 seconds at 25°C)  
30 pF and above: ≥ 1,000  
Below 30 pF: ≥ 400 +(20xC)*  
Quality Factor (Q)  
See “Dissipation Factor”  
Dissipation Factor (tanδ) at +25°C2  
Insulation Resistance (IR) Limit at +25°C  
*C = Nominal capacitance  
2.50%  
2.50%  
5.0%  
See “Quality Factor”  
10,000 MΩ Minimum  
(500 VDC applied for 60±5 seconds at 25°C)  
1 The distance between the adjacent leads of the component (also referred to as "lead spacing") governs Dielectric Withstanding Voltage (DWV) limit.  
2 Capacitance and Dissipation Factor (DF) measured under the following conditions:  
SL: 1 MHz ± 100 kHz and 1.0 ±0.2 Vrms  
X5P, Y5U and Y5V: 1 kHz ± 50 Hz and 1.0 ±0.2 Vrms  
Note: When measuring capacitance, it is important to ensure the set voltage level is held constant. The HP4284 and Agilent E4980 have a feature known  
as Automatic Level Control (ALC). The ALC feature should be switched to "ON."  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
C1064_X1_400 VAC_Y2_250 VAC • 8/4/2017  
4
Radial Leaded Ceramic Disc Capacitors  
Safety Standard Recognized, C900, Encapsulated, AC Type, X1 400 VAC/Y2 250 VAC (Industrial Grade)  
Table 1 – Product Ordering Codes and Ratings  
Dimensions (mm)  
Lead Spacing  
Dielectric/  
Temp. Char.  
KEMET  
Part Number  
Capacitance  
Tolerance  
Capacitance  
Body Diameter  
(Maximum)  
Body Thickness  
(Maximum)  
Lead  
Diameter  
Bulk  
Ammo  
Packaging Packaging  
C90(1)U100JYSD(2)A(3)  
C90(1)U120JYSD(2)A(3)  
C90(1)U150JYSD(2)A(3)  
C90(1)U180JYSD(2)A(3)  
C90(1)U200JYSD(2)A(3)  
C90(1)U220JYSD(2)A(3)  
C90(1)U240JYSD(2)A(3)  
C90(1)U270JYSD(2)A(3)  
C90(1)U300JYSD(2)A(3)  
C90(1)U330JYSD(2)A(3)  
C90(1)U360JYSD(2)A(3)  
C90(1)U390JYSD(2)A(3)  
C90(1)U470JYSD(2)A(3)  
C90(1)U500JYSD(2)A(3)  
C90(1)U510JYSD(2)A(3)  
C91(1)U560JYSD(2)A(3)  
C91(1)U620JYSD(2)A(3)  
C91(1)U680JYSD(2)A(3)  
C91(1)U750JYSD(2)A(3)  
C92(1)U820JYSD(2)A(3)  
C93(1)U101JYSD(2)A(3)  
10 pF  
12 pF  
15 pF  
18 pF  
20 pF  
22 pF  
24 pF  
27 pF  
30 pF  
33 pF  
36 pF  
39 pF  
47 pF  
50 pF  
51 pF  
56 pF  
62 pF  
68 pF  
75 pF  
82 pF  
100 pF  
7.0  
5 mm,  
7.5 mm,  
or  
SL  
±5%  
5.0  
0.55 ±0.1  
10 mm  
8.0  
9.0  
10.0  
C90(1)U101KYYD(2)A(3)  
C90(1)U151KYYD(2)A(3)  
C90(1)U221KYYD(2)A(3)  
C90(1)U331KYYD(2)A(3)  
C90(1)U471KYYD(2)A(3)  
C91(1)U561KYYD(2)A(3)  
C91(1)U681KYYD(2)A(3)  
C92(1)U821KYYD(2)A(3)  
C92(1)U102KYYD(2)A(3)  
100 pF  
150 pF  
220 pF  
330 pF  
470 pF  
560 pF  
680 pF  
820 pF  
1,000 pF  
7.0  
5 mm,  
7.5 mm,  
or  
Y5P  
±10%  
5.0  
0.55 ±0.1  
10 mm  
8.0  
9.0  
C90(1)U102MYWD(2)A(3)  
C92(1)U152MYWD(2)A(3)  
C92(1)U222MYWD(2)A(3)  
C94(1)U332MYWD(2)A(3)  
C96(1)U392MYWD(2)A(3)  
C96(1)U472MYWD(2)A(3)  
1,000 pF  
1,500 pF  
2,200 pF  
3,300 pF  
3,900 pF  
4,700 pF  
7.0  
9.0  
5 mm, 7.5 mm, or 10 mm  
7.5 mm or 10 mm  
Y5U  
±20%  
5.0  
5.0  
0.55 ±0.1  
11.0  
13.0  
C90(1)U102MYVD(2)A(3)  
C90(1)U152MYVD(2)A(3)  
C90(1)U222MYVD(2)A(3)  
C92(1)U332MYVD(2)A(3)  
C94(1)U392MYVD(2)A(3)  
C94(1)U472MYVD(2)A(3)  
C96(1)U682MYVD(2)A(3)  
C98(1)U103MYVD(2)A(3)  
1,000 pF  
1,500 pF  
2,200 pF  
3,300 pF  
3,900 pF  
4,700 pF  
6,800 pF  
10,000 pF  
7.0  
5 mm, 7.5 mm, or 10 mm  
7.5 mm or 10 mm  
Lead Spacing  
9.0  
Y5V  
±20%  
0.55 ±0.1  
11.0  
13.0  
15.0  
Body Diameter  
(Maximum)  
Body Thickness  
(Maximum)  
KEMET Part Number  
Capacitance  
Capacitance Tolerance  
Lead Diameter  
(1) To properly complete ordering code, insert the one-digit numeric code to reflect required lead spacing: (Note that select capacitance values and packaging  
options may limit lead spacing availability. See table above to verify availability.)  
5 = 5.0 mm  
7 = 7.5 mm  
1 = 10.0 mm  
(2) To properly complete ordering code, insert the one-digit character code to reflect the required lead configuration: (See "Lead Configuration" section of this  
document, page 2, for further details.)  
A = Straight  
B = Vertical Kink  
C = Outside Kink  
D = Inside Kink (not available with 5 mm lead spacing option)  
(3) To properly complete ordering code, enter the four-digit numeric or alphanumeric "Packaging C-Spec Ordering Code." See "Dimensions" section of this  
document, page 2, for available options.  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
C1064_X1_400 VAC_Y2_250 VAC • 8/4/2017  
5
Radial Leaded Ceramic Disc Capacitors  
Safety Standard Recognized, C900, Encapsulated, AC Type, X1 400 VAC/Y2 250 VAC (Industrial Grade)  
Table 2 – Performance & Reliability: Test Methods and Conditions  
Item  
Specification  
Test Method  
−40°C to +125°C  
Operating Temperature Range  
The capacitor shall not be damaged when voltage is applied  
between the lead wires for 60 seconds.  
Between lead  
wires  
No failures  
2,000 VAC(rms) – 5.0 mm lead spacing  
2,600 VAC(rms) – 7.5 mm and 10 mm lead spacing  
The terminals (leads) of the capacitor  
shall be connected together. A metal foil  
is tightly wrapped around the body of the  
capacitor at a distance of about 3 to 4 mm  
Dielectric  
Strength  
ꢀetal  
ꢁoil  
Body Insulation  
No failures  
from each terminal. The capacitor is then  
aꢃout  
ꢄ to 4 mm  
inserted into a container filled with metal  
balls approximately 1 mm in diameter. 2,600  
VAC(rms) is applied for 60 seconds between  
the capacitor lead wires and metal balls.  
ꢀetal  
ꢂalls  
The insulation resistance shall be measured with 500 ±50 VDC  
applied after 60 ±5 seconds of charging.  
Insulation Resistance (IR)  
10,000 MΩ minimum  
Capacitance  
Within specified tolerance  
Temperature  
Characteristics  
Specification  
Y5P, Y5U and Y5V: Capacitance is measured at 1 kHz ±20% and 5  
Vrms or less. (20 ±2°C)  
SL: Capacitance is measured at 1 MHz ±20% and 1.0 ±0.2 Vrms  
(25°C)  
Y5P, Y5U  
DF ≤ 2.5%  
DF ≤ 5.0%  
Y5V  
Dissipation Factor (DF) or Q  
≥ 30 pF: Q ≥ 1000  
< 30 pF: Q ≥ 400  
+(20 x C)  
SL  
C = Nominal  
capacitance  
A capacitance measurement is made at each step specified:  
Step  
Temperature  
+20 ±2°C  
−25 ±2°C  
Temperature  
Characteristics  
Capacitance  
Change  
1
2
Y5P  
Y5U  
Y5V  
Within ±10%  
3
+20 ±2°C  
+85 ±2°C  
+20 ±2°C  
Temperature Characteristics  
Within +20%/−55%  
Within ~+30%/−80%  
4
5
−1,000 ~+350 ppm°C  
(+20°C ~+85°C)  
SL  
Pretreatment:  
Capacitor is stored at 85 ±2°C for 1 hour and then placed at room  
condition1 for 24 ±2 hours before measurement.  
With the termination in its normal position, the specimen is held  
by its body in such a manner that the axis of the termination is  
vertical; a tensile force of 10 N is applied to the termination in the  
direction of its axis and acting in a direction away from the body  
of the specimen.  
Lead wire or capacitor body shall not  
Tensile  
break.  
With the termination in its normal position, the specimen is held  
by its body in such a manner that the axis of the termination is  
vertical; a mass force of 5 N is then suspended from the end of  
the termination. The body of the specimen is then inclined within  
a period of 2 to 3 seconds, through an angle of approximately 90°  
in the vertical plane and then resumed to its initial position over  
the same period of time; this operation constitutes one bend.  
One bend immediately followed by a second bend in the opposite  
direction.  
Terminal  
Strength  
Lead wire or capacitor body shall not  
Bending  
break.  
1 “Room Condition” is defined as follows: Temperature: 15 ~ 35°C/Humidity: 45 ~ 75%/Atmospheric Pressure: 86 ~ 106 kPa.  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
C1064_X1_400 VAC_Y2_250 VAC • 8/4/2017  
6
Radial Leaded Ceramic Disc Capacitors  
Safety Standard Recognized, C900, Encapsulated, AC Type, X1 400 VAC/Y2 250 VAC (Industrial Grade)  
Table 2 – Performance & Reliability: Test Methods and Conditions cont'd  
Item  
Specification  
Test Method  
The lead wire of the capacitor is dipped into molten solder for 5  
±0.5 seconds. The depth of immersion is up to 1.5 mm  
(+5/−0 mm) from the root of lead wires.  
Solder Temperature: lead-free solder (Sn-3Ag – 0.5Cu)  
245°C ±5°C.  
Lead wire should have a uniform coating  
of solder in the axial direction and over  
3/4 of its circumference.  
Solderability  
As shown in the figure below, the lead wires are immersed in  
molten solder up to 1.5 mm(+5/−0 mm) from the end of the epoxy  
meniscus (root of lead wire).  
No visual defect  
1,000 MΩ  
Appearance  
IR  
Duration/Solder Temp: 3.5 ±0.5 seconds/350°C ±10°C or 10 ±1  
seconds/260°C ±5°C  
Dielectric  
Strength  
Per item 1  
Tꢂermal  
Screen  
Capacitor  
Soldering Effect  
(Non-Preheat)  
1ꢁ5 to  
2ꢁ0 mm  
ꢀolten  
Solder  
Y5P, Y5U and Y5V: within ±10%  
Capacitance SL: within ±2.5% or ±0.25 pF, whichever is  
Pretreatment: Capacitor is stored at 85°C ±2°C for 1 hour and  
then placed at room condition1 for 24 ±2 hours before initial  
measurements.  
larger.  
Post-treatment: Capacitor is stored for 1 to 2 hours at room  
condition1.  
Capacitor is stored at 120°C +0/−5°C for 60 +0/−5 seconds.  
Then, as shown in the figure below , the lead wires are immersed  
in molten solder up to 1.5 mm (+5/−0mm) from the end of the  
epoxy meniscus (root of lead wire).  
Appearance  
No visual defect  
1,000 MΩ  
IR  
Dielectric  
Strength  
Duration/Solder Temperature 7.5+0/−1 second/260°C ±5°C.  
Per item 1  
Tꢂermal  
Screen  
Capacitor  
Soldering Effect  
(Preheat)  
1ꢁ5 to  
2ꢁ0 mm  
ꢀolten  
Solder  
Y5P, Y5U and Y5V: within ±10%  
Capacitance SL: within ±2.5% or ±0.25 pF, whichever is  
Pretreatment: Capacitor is stored at 85°C ±2°C for 1 hour and  
then placed at room condition1 for 24 ±2 hours before initial  
measurements.  
larger.  
Post-treatment: Capacitor is stored for 1 to 2 hours at room  
condition1.  
Appearance  
Capacitance  
No visual defect  
Steady State Humidity:  
Load Humidity:  
Temperature  
Characteristics  
Capacitance  
Change  
Y5P  
Y5U  
Y5V  
Within ±10%  
Within ±20%  
Within ±30%  
90 to 95% humidity at 40°C  
±2°C for 500 ±12 hours with  
full rated voltage applied.  
Within ±2.5% or  
±0.25 pF, whichever  
is larger.  
90 to 95% humidity at 40°C  
±2°C for 500 ±12 hours.  
SL  
Biased Humidity  
Post-treatment:  
Post-treatment:  
Y5P and Y5U: 5.0% maximum  
Capacitor is stored for 1 to 2  
DF  
Q
Capacitor is stored for 1 to 2  
hours at room condition1.  
Y5V: 7.5% maximum  
SL: Less than 30 pF:  
hours at room condition1.  
Q ≥ 100 + 10 × C/3  
More than 30 pF: Q ≥ 200  
C = Nominal capacitance  
Y5P, Y5V and Y5U: 3,000 MΩ minimum  
SL: 1,000 MΩ minimum  
IR  
Dielectric  
Strength  
No failures  
1 “Room Condition” is defined as follows: Temperature: 15 ~ 35°C/Humidity: 45 ~ 75%/Atmospheric Pressure: 86 ~ 106 kPa.  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com C1064_X1_400 VAC_Y2_250 VAC • 8/4/2017  
7
Radial Leaded Ceramic Disc Capacitors  
Safety Standard Recognized, C900, Encapsulated, AC Type, X1 400 VAC/Y2 250 VAC (Industrial Grade)  
Table 2 – Performance & Reliability: Test Methods and Conditions cont'd  
Item  
Specification  
Test Method  
Impulse Voltage: Each individual capacitor is subjected to three 5  
No visual defect  
Appearance  
kv impulses prior to life testing.  
Y5P, Y5V and Y5U: within ±20%  
SL: within ±3 or ±0.3 pF,  
whichever is larger.  
Capacitance  
Change  
Cꢀ tr td  
ꢀR  
Vp  
(uꢀ) (uS) (uS)  
0ꢀ01 1ꢀ2 4ꢀ  
0ꢀ1 1ꢀ5 4ꢀ  
0ꢀ9Vp  
ꢀꢀ  
3,000 MΩ minimum  
SL: 1,000 MΩ minimum  
IR  
0ꢀ5Vp  
High  
Temperature  
Life  
tr  
td  
Dielectric  
Strength  
Time  
No failures  
Capacitors are placed in a circulating air oven for a period of  
1,000 hours. The air in the oven is maintained at a temperature of  
125°C ±2 throughout the test. The capacitors are subjected to AC  
425 Vrms. Each hour the voltage is increased to AC 1,000 Vrms  
for 0.1 seconds.  
The capacitor is exposed to a flame for 15 seconds and then  
removed for 15 seconds. This test is repeated for 5 cycles.  
The capacitor flame extinguishes as  
follows:  
Capacitor  
ꢂlame  
Cycle  
Time  
ꢀꢁ  
Flame Test  
30 seconds  
maximum  
ꢃꢄ  
1 ~ 4  
12ꢀ  
60 seconds  
maximum  
Gas ꢆurner  
5
20ꢅ  
(ꢇnitꢈmm)  
The capacitors are individually wrapped in at least one, but not  
more than two, complete layers of cheesecloth. They are then  
subjected to 20 discharges. The interval between successive  
discharges is 5 seconds. The VAC is maintained for 2 minutes  
after the last discharge.  
L1  
L2  
R
S1  
C1  
Vac  
C2  
Lꢀ  
CCX  
L4  
Ct  
Vt  
S2  
Tr  
ꢂscilloscope  
C1, 2  
L1-4  
R
1 μF ±10%  
C3  
Cx  
VAC  
VR  
0.033 μF ±5% 10 kV  
Test capacitor  
VR ±5%  
Active Flammability  
The cheesecloth should not ignite.  
1.5 Mh ±20% 16A Rod core choke  
100 ±2%  
Ct  
F
3 μF ±5% 10 kV  
Rated Voltage  
Voltage applied to Ct  
Fuse, Rated 10A  
Vt  
Vꢀ  
5ꢁV  
time  
1 “Room Condition” is defined as follows: Temperature: 15 ~ 35°C/Humidity: 45 ~ 75%/Atmospheric Pressure: 86 ~ 106 kPa.  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
C1064_X1_400 VAC_Y2_250 VAC • 8/4/2017  
8
Radial Leaded Ceramic Disc Capacitors  
Safety Standard Recognized, C900, Encapsulated, AC Type, X1 400 VAC/Y2 250 VAC (Industrial Grade)  
Table 2 – Performance & Reliability: Test Methods and Conditions cont'd  
Item  
Specification  
Test Method  
The capacitor under test is held into a flame and in a position  
which best promotes burning. Each specimen is exposed to the  
flame once.  
Test Specimen  
200  
ꢀ5mm  
45ꢃ  
Tissue  
The burning time should not exceed 30  
seconds.  
The tissue paper should not ignite.  
Passive Flammability  
Aꢁout 10mm  
Tꢄicꢅ ꢆoard  
Time of exposure to flame:  
Length of flame:  
30 seconds  
12 ±1 mm  
35 mm minimum  
0.5 ±0.1 mm  
Gas burner length:  
Inside diameter:  
Outside diameter:  
Gas butane gas purity:  
0.9 mm maximum  
95% minimum  
Appearance  
No visual defect  
Temperature  
Characteristics  
Capacitance  
Change  
The capacitor is subjected to 5 temperature cycles.  
Temperature Cycle  
Dwell  
SL  
Y5P  
Within ±5%  
Within ±10%  
Within ±20%  
Capacitance  
Transition  
Time  
Step Temperature (°C)  
Time  
Y5U, Y5V  
(minutes) (minutes)  
1
2
3
4
−40 +0/−3  
Room temperature  
125 +3/−0  
30  
SL  
≥ 30 pF: Q ≥ 350  
< 30 pF: Q ≥ 275  
+5/2C  
C = Nominal  
capacitance  
Temperature  
3
Cycle  
3
30  
DF/Q  
IR  
Room temperature  
3
Y5P  
DF ≤ 5%  
Pretreatment: Capacitor shall be stored at 85 ±2 for 1 hour then  
placed at room condition1 for 24 ±2 hours.  
Y5U, Y5V  
DF ≤ 7.5%  
3,000 MΩ minimum  
SL: 1,000 MΩ minimum  
Post-treatment: Capacitor is stored for 1 to 2 hours at room  
condition1.  
Dielectric  
Strength  
No failures  
1 “Room Condition” is defined as follows: Temperature: 15 ~ 35°C/Humidity: 45 ~ 75%/Atmospheric Pressure: 86 ~ 106 kPa.  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
C1064_X1_400 VAC_Y2_250 VAC • 8/4/2017  
9
Radial Leaded Ceramic Disc Capacitors  
Safety Standard Recognized, C900, Encapsulated, AC Type, X1 400 VAC/Y2 250 VAC (Industrial Grade)  
Soldering and Mounting Information  
Soldering:  
When soldering this product to a PCB/PWB, do not exceed the solder heat resistance specification of the capacitor.  
Subjecting this product to excessive heating could reflow the solder joint between the lead and ceramic element and/or may  
result in thermal shocks that can crack the ceramic element.  
When soldering these capacitors with a soldering iron, it should be performed under the following conditions:  
• Temperature of iron-tip: 400°C maximum  
• Soldering iron wattage: 50 W maximum  
• Soldering time: 3.5 seconds maximum  
Cleaning (ultrasonic cleaning):  
To perform ultrasonic cleaning, observe the following conditions:  
• Rinse bath capacity: output of 20 watts per liter or less  
• Rinsing time: 5 minute maximum  
• Do not vibrate the PCB/PWB directly  
• Excessive ultrasonic cleaning may lead to fatigue destruction of the lead wires  
Construction  
Detailed Cross Section  
Epoꢀy Encapsulation  
(0ꢁ4 mm ꢂinimum Tꢃicꢄness,  
ꢅigment ꢆ ꢇlue/ꢈL 94 Vꢉ0)  
Lead Attacꢃ Solder  
(Sn9ꢊꢁ5/Agꢋ/Cu0ꢁ5)  
Dielectric  
material  
(ꢇaTiꢒ)  
Electrode  
(Ag ꢌ Glass frit)  
Electrode  
(Ag ꢌ Glass frit)  
Lead ꢑire  
Lead Attacꢃ Solder  
(Sn9ꢊꢁ5/Agꢋ/Cu0ꢁ5)  
Steel  
Cu  
Core ꢂetal  
Dielectric  
ꢇarrier Layer  
material  
(ꢇaTiꢒ)  
100ꢎ Sn  
(ꢋꢉꢏ ꢐm)  
ꢍinisꢃ Layer  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
C1064_X1_400 VAC_Y2_250 VAC • 8/4/2017 10  
Radial Leaded Ceramic Disc Capacitors  
Safety Standard Recognized, C900, Encapsulated, AC Type, X1 400 VAC/Y2 250 VAC (Industrial Grade)  
Marking  
These capacitors shall be stamped or laser marked with KEMET's trademark, type designation, capacitor class, rated voltage,  
rated capacitance and capacitance tolerance codes. In addition, all devices are marked with the recognized approval mark  
and a date/lot code for traceability. Marking will be supplied either on one side or both sides of the encapsulated capacitor  
body. All marking shall be legible to allow for clear identification of the component. Marking appears in legible contrast.  
Illustrated below is an example of the marking format and content. (Two sided marking is limited to capacitors with body  
diameters ≤ 8.0 mm.)  
Single Sided  
Rated Capacitance  
(ꢆ ꢄumeric Cꢉaracters)  
ꢊEꢋET ID  
Type Designation  
(2 Cꢉaracters)  
Capacitance Tolerance Code  
(1 Cꢉaracter)  
VDE ꢃ EꢄEC  
approꢁal marꢂs  
IEC ꢅ0ꢆꢇ4ꢈ14 ꢆrd  
(2005)  
Capacitor Class  
and Rated Voltage  
ꢀL approꢁal marꢂ  
Date/Lot Code  
(See Taꢌle ꢍeloꢎ)  
Double Sided  
Front  
Back  
ꢋL approꢅal marꢆ  
Rated Capacitance  
(ꢈ ꢄumeric Cꢂaracters)  
ꢀEꢁET ID  
Capacitance  
Tolerance Code  
(1 Cꢂaracter)  
Type Designation  
(2 Cꢂaracters)  
VDE ꢃ EꢄEC  
approꢅal marꢆs  
IEC ꢇ0ꢈꢉ4ꢊ14 ꢈrd  
(2005)  
Capacitor Class  
and Rated Voltage  
Date/Lot Code  
(See Taꢌle ꢍeloꢎ)  
Date/Lot Code Explanation  
6
C
6
1234  
Manufacturing  
Month:  
Last digit of year,  
e.g.,  
Manufacturing  
Location Code  
Last 4 digits of  
lot no.  
1-9 = Jan - Sept  
A = October  
N = November  
D = December  
6 = 2016  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
C1064_X1_400 VAC_Y2_250 VAC • 8/4/2017 11  
Radial Leaded Ceramic Disc Capacitors  
Safety Standard Recognized, C900, Encapsulated, AC Type, X1 400 VAC/Y2 250 VAC (Industrial Grade)  
Packaging Quantities  
Ammo Pack (Carrier Tape)  
Component pitch on carrier tape2  
Capacitor  
Body Diameter  
(mm)  
Body Diameter  
Code1  
Bulk Bag  
(Loose)  
12.7 mm  
15 mm  
25.4 mm  
7.0  
8.0  
0
1
2
3
4
5
6
7
8
9.0  
1,000 pieces/box  
10.0  
11.0  
12.0  
13.0  
14.0  
15.0  
500 pieces/bag  
1,000 pieces/box  
500 pieces/box  
1 The "Body Diameter Code" is located in the third character position of the ordering code. This code identifies the maximum diameter of the capacitor  
body in millimeters. For more information regarding the ordering code, see "Ordering Information" section of this document.  
2 For details regarding component pitch on carrier tape, see "Ammo Pack Taping Format" and "Ammo Pack Taping Specifications" sections of this  
document.  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
C1064_X1_400 VAC_Y2_250 VAC • 8/4/2017 12  
Radial Leaded Ceramic Disc Capacitors  
Safety Standard Recognized, C900, Encapsulated, AC Type, X1 400 VAC/Y2 250 VAC (Industrial Grade)  
Figure 1 - Ammo Pack Taping Format  
5 mm and 7.5 mm Lead Spacing:  
S  
2  
D
e
ꢄd  
1  
2  
0  
0  
1 0 2  
T maꢀimum  
ꢁarꢂing Side  
L
1  
ꢄD0  
0  
10 mm Lead Spacing:  
S  
2  
D
t2  
t1  
e
1  
2  
0  
ꢄd  
0  
L
1  
0  
ꢄD0  
Table 3 – Ammo Pack Taping Specifications  
Lead Spacing  
5 mm  
7.5 mm  
10 mm  
Lead Style  
Item  
Straight  
Preformed1  
Straight  
Preformed1  
Straight  
Preformed1  
Symbol  
Dimensions (mm)  
Lead Spacing  
Component Pitch  
Sprocket Hole Pitch  
F
P
5.0+0.8/−0.2  
7.5±1.0  
15.0  
10.0±1.0  
12.7  
25.4±2  
P0  
12.7±0.3  
15.0±0.3  
12.7±0.3  
Sprocket Hole Center to  
P2  
P1  
6.35±1.5  
3.75±1.0  
7.5±1.5  
12.7±1.5  
7.7±1.5  
Component Center  
Sprocket Hole Center to Lead  
3.75±1.0  
Center  
Body Diameter  
Component Alignment (side/side)  
Carrier Tape Width  
D
See "Product Ordering Codes and Ratings" section of this document.  
∆S  
W
0±2.0  
18.0+1.0/−0.5  
9.0±0.5  
Sprocket Hole Position  
W1  
1 Prefromed (crimped) lead configurations include vertical kink, outside kink and inside kink. See "Lead Configurations" and "Ordering Information"  
sections of this document for further details.  
2 Also referred to as "lead length" in this document.  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
C1064_X1_400 VAC_Y2_250 VAC • 8/4/2017 13  
Radial Leaded Ceramic Disc Capacitors  
Safety Standard Recognized, C900, Encapsulated, AC Type, X1 400 VAC/Y2 250 VAC (Industrial Grade)  
Table 3 – Ammo Pack Taping Specifications cont'd  
Lead Spacing  
5 mm  
7.5 mm  
10 mm  
Lead Style  
Straight  
Preformed1  
Straight  
Preformed1  
Straight  
Preformed1  
Item  
Symbol  
H0  
Dimensions (mm)  
Height to Seating Plane2  
N/A  
18.0 +2.0/-0  
N/A  
N/A  
20.0 +1.5/-1.0  
18.0 +2.0/-0  
N/A  
N/A  
18.0 +2.0/-0  
N/A  
(preformed leads1)  
Height to Seating Plane2  
(straight leads)  
H
20.0 +1.5/-1.0  
20.0 +1.5/-1.0  
Lead Protrusion  
Diameter of Sprocket Hole  
Lead Diameter  
D0  
φd  
t1  
2.0 maximum  
4.0 ±0.2  
0.55 ±0.1  
0.6 ±0.3  
Carrier Tape Thickness  
Total Thickness (Carrier Tape,  
Hold-Down Tape and Lead)  
t2  
1.5 maximum  
∆h1  
∆h2  
L
Component Alignment (front/  
back )  
2.0 maximum  
11.0 maximum  
Cut Out Length  
Hold-Down Tape Width  
Hold-Down Tape Position  
W0  
W2  
11.0 minimum  
3.0 maximum  
11.5 minimum  
1.5 ±1.5  
Coating Extension on Leads  
(meniscus)  
e
3.0 maximum for straight lead; not to exceed the bend for preformed1 lead configurations.  
See "Product Ordering Codes and Ratings" section of this document.  
Body Thickness  
T
1 Prefromed (crimped) lead configurations include vertical kink, outside kink and inside kink. See "Lead Configurations" and "Ordering Information"  
sections of this document for further details.  
2 Also referred to as "lead length" in this document.  
Application Notes:  
Storage and Operating Conditions:  
The Insulating coating of these devices does not form an air and moisture tight seal. Avoid exposure to moisture and do not  
use or store these devices in a corrosive atmosphere, especially where chloride gas, sulfide gas, acid, alkali, salt or the like  
are present. Before cleaning, bonding or molding these devices, it is important to verify that your process does not affect  
product quality and performance. KEMET recommends testing and evaluating the performance of a cleaned, bonded or  
molded product prior to implementing and/or qualifying any of these processes. Store the capacitors where the temperature  
and relative humidity do not exceed 40 degrees centigrade and 70% respectively. For optimum solderability, capacitor stock  
should be used promptly, preferably within 6 months of receipt.  
Working Voltage:  
Application voltage (Vp-p or Vo-p) must not exceed the voltage rating of the capacitor. Irregular voltages can be generated  
for a transient period of time when voltage is initially applied and/or removed from a circuit. It is important to choose a  
capacitor with a voltage rating greater than or equal to these irregular voltages.  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
C1064_X1_400 VAC_Y2_250 VAC • 8/4/2017 14  
Radial Leaded Ceramic Disc Capacitors  
Safety Standard Recognized, C900, Encapsulated, AC Type, X1 400 VAC/Y2 250 VAC (Industrial Grade)  
Operating Temperature and Self-Generating Heat:  
The surface temperature of a capacitor should be kept below the upper limit of its rated operating temperature range. Be  
sure to take into account the heat generated by the capacitor itself. When the capacitor is used in a high-frequency current,  
pulse current or similar current, it may self-generate heat due to dielectric loss. Temperature rise due to self-generated  
heating should not exceed 20°C (while operated at an atmosphere temperature of 25°C).  
Handling - Vibration and Impact:  
Do not expose these devices or their leads to excessive shock or vibration during use.  
FAILURE TO FOLLOW THE ABOVE CAUTIONS MAY RESULT, WORST CASE, IN A SHORT CIRCUIT AND CAUSE FUMING OR  
PARTIAL DISPERSION WHEN THE PRODUCT IS USED.  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
C1064_X1_400 VAC_Y2_250 VAC • 8/4/2017 15  
Radial Leaded Ceramic Disc Capacitors  
Safety Standard Recognized, C900, Encapsulated, AC Type, X1 400 VAC/Y2 250 VAC (Industrial Grade)  
KEMET Electronics Corporation Sales Offices  
For a complete list of our global sales offices, please visit www.kemet.com/sales.  
Disclaimer  
All product specifications, statements, information and data (collectively, the “Information”) in this datasheet are subject to change. The customer is responsible for  
checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed.  
All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied.  
Statements of suitability for certain applications are based on KEMET Electronics Corporation’s (“KEMET”) knowledge of typical operating conditions for such  
applications, but are not intended to constitute – and KEMET specifically disclaims – any warranty concerning suitability for a specific customer application or use.  
The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any  
technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no  
obligation or liability for the advice given or results obtained.  
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component  
failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards  
(such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or  
property damage.  
Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicated or that other  
measures may not be required.  
KEMET is a registered trademark of KEMET Electronics Corporation.  
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com  
C1064_X1_400 VAC_Y2_250 VAC • 8/4/2017 16  
配单直通车
C901U222MYVDBA7317产品参数
型号:C901U222MYVDBA7317
是否无铅: 不含铅
是否Rohs认证: 符合
生命周期:Active
IHS 制造商:KEMET ELECTRONICS CORP
包装说明:RADIAL LEADED
Reach Compliance Code:compliant
ECCN代码:EAR99
Factory Lead Time:79 weeks
风险等级:1.65
其他特性:CLASS X1 AND Y2 FOR SAFETY REGULATION
电容:0.0022 µF
电容器类型:CERAMIC CAPACITOR
介电材料:CERAMIC
高度:7 mm
JESD-609代码:e3
长度:7 mm
安装特点:THROUGH HOLE MOUNT
多层:No
负容差:20%
端子数量:2
最高工作温度:125 °C
最低工作温度:-40 °C
封装形状:DISK PACKAGE
封装形式:Radial
包装方法:Ammo Pack
正容差:20%
额定(AC)电压(URac):400 V
参考标准:IEC60384-14
表面贴装:NO
温度特性代码:Y5V
温度系数:-80/+30% ppm/ °C
端子面层:Tin (Sn)
端子节距:10 mm
端子形状:WIRE
宽度:5 mm