CCF1F
chip current fuses
applications and ratings (continued)
Fusing
Characteristics
Normal
Melting
Operating
Temperature
Range
Part
Designation
Current
Rating
Voltage
Rating
Interrupting
Capacity
Internal R.
(mΩ) Max.
Rated
Current
Fusing
Time
l2t (A2, sec.)
CCF1F3.15
CCF1F4
3.15A
4A
26.0
20.1
15.3
11.4
10.6
9.5
2.37
3.85
6.5
UNDER
DEVELOP.
CCF1F5
5A
UL(c-UL)
AC 125V
DC 125V
UL(c-UL)
UL(c-UL)
100%
AC125V 50A
DC125V 50A
CCF1F6.3
CCF1F7
6.3A
7A
10.6
12.8
17.0
27.7
4 hour min.
-55°C
to
+125°C
200%
120 sec. max.
CCF1F8
8A
1000%
0.001 sec. min.
0.01 sec. max.
CCF1F10
10A
7.5
UL(c-UL)
AC 65V
DC 65V
UL(c-UL)
AC65V 50A
DC65V 50A
CCF1F12
CCF1F15
12A
15A
4.5
3.5
73.5
125.5
environmental applications
Derating Curve
Fusing Characteristics
1.5
1.4
1.3
1.2
1.1
10
1
0.1
1.0
0.9
0.8
0.7
0.6
0.5
0.01
0.001
-55 -35 -15
5
25
45
65
85
105 125
1
10
100
1000
Fusing Current
(A)
Ambient Temperature
(°C)
Stationary Current: Regard the peak of stationary current waveform as
stationary current value when the stationary current is repeated pulse.
Normal derating of this product should be 0.7max. as standards.
Deratings by ambient temperatures.
When using the products at the temperatures other than normal
temperature (25°C ± 5°), temperature adjustment will be required.
Please refer the derating coefficient as shown in the figure.
Performance Characteristics
Requirements
Test
Parameter
Limit
Ref.
Test Method
Within specified time. Insulation
resistance shall not be less than 0.1MΩ
Fusing time measured under 2/N (rated current 200%) and 10/N
(rated current 1000%)
IEC60127-4
9.2
Fusing Characteristics
Maximum temperature rise
95°C and not fusing (7A or less)
IEC60127-4
9.7
Surface temperature should be measured by 1.25/N
Surface temperature should be measured by 1.00/N
Surface Temperature Rise
Voltage Drop
Maximum temperature rise 75°C
and not fusing (all the rating)
UL248.14
When the fuse-link has carried its rated current for a time sufficient
to reach temperature stability
IEC60127-4
9.1
Refer to ratings table
At the end of electrify test to 1.25/N the voltage drop across
the fuse-link is measured and used for the calculation of the
sustained dissipation
Maximum Sustained
Dissipation
IEC60127-4
9.5
Refer to ratings table
Distance between holding points 90mm, bent by 1mm at rate
of 1mm/second
IEC60127-4
8.3
Shall not exceed
the ratings table
Bending Test
Shall not exceed
the ratings table
IEC60127-4 260°C ± 5°C, 10 seconds ± 0.5 seconds, After the solder depth,
Resistance to Soldering Heat
Rapid Change of Temperature
8.7
voltage drop across the fuse-link is measured
––
-55°C (30 minutes), +125°C (30 minutes), 100 cycles
∆R±10%
Specifications given herein may be changed at any time without prior notice. Please confirm technical specifications before you order and/or use.
1/04/13
—
256