27
Note:
eleCTꢅiCAl ChAꢅACTeꢅisTiCs
sTYle
CFꢅ-12
1/6W
150V
CFꢅ25s CFꢅ-25
CFꢅ50s CFꢅ-50 CFꢅ1Ws CFꢅ100 CFꢅ2Ws CFꢅ200 CFꢅ3Ws
Power Rating at 70°C
Maximum WorkingVoltage
Maximum OverloadVoltage
Voltage Proof on Insulation
Resistance Range
1/4W
1/2W
300V
600V
1W
2W
3W
200V
400V
400V
250V
500V
500V
350V
700V
400V
800V
700V
500V
300V
1,000V
1,000V
300V
1Ω - 10MΩ & 0Ω for E24 series value
-55°C to +155°C
OperatingTemp. Range
Temperature Coefficient
seeTable 1
Note: Special value is available on request
eNViꢅoNMeNTAl ChAꢅACTeꢅisTiCs
PeꢅFoꢅMANCe TesT
ShortTime Overload
Voltage Proof on Insulation
Temperature Coefficient
Insulation Resistance
Solderability
TesT MeThoD
IEC 60115-1 4.13
IEC 60115-1 4.7
IEC 60115-1 4.8
IEC 60115-1 4.6
IEC 60115-1 4.17
APPꢅAise
2.5 times RCWV for 5 Sec.
±0.75%+0.05Ω
By type
inV-block for 60 Sec., test voltage by type
-55°C to +155°C
By type
inV-block for 60 Sec.
>1,000MΩ
95% Min. coverage
235±5°C for 3±0.5 Sec.
No deterioration of
coatings and markings
Solvent Resistance of Marking
IEC 60115-1 4.30
IPA for 5±0.5 Min. with ultrasonic
Robustness ofTerminations
Periodic-pulse Overload
Damp Heat Steady State
Endurance at 70°C
IEC 60115-1 4.16
IEC 60115-1 4.39
IEC 60115-1 4.24
IEC 60115-1 4.25
IEC 60115-1 4.19
IEC 60115-1 4.18
Direct load for 10 Sec. in the direction of the terminal leads
4 times RCWV 10,000 cycles (1 Sec. on, 25 Sec. off)
≥2.5kg (24.5N)
±1.0%+0.05Ω
±3.0%+0.05Ω
±3.0%+0.05Ω
±1.0%+0.05Ω
±1.0%+0.05Ω
40±2°C, 90-95% RH for 56 days, loaded with 0.1 times RCWV
70±2°C at RCWV for 1,000 Hr. (1.5 Hr. on, 0.5 Hr. off)
-55°C RoomTemp. +155°C RoomTemp. (5 cycles)
Temperature Cycling
Resistance to Soldering Heat
260±3°C for 10±1 Sec., immersed to a point 3±0.5mm from the body
Revision: 201304
Note: RCWV(Rated Continuous WorkingVoltage) = Power Rating x ResistanceValue or Max. working voltage listed above, whichever less.