Product specification
17
19
16V to 3KV
NPO & X7R
Surface-Mount Ceramic Multilayer Capacitors
Soft Termination
TEST
TEST METHOD
4.11
PROCEDURE
REQUIREMENTS
Rapid Change of
Temperature
Preconditioning;
150 +0/–10 °C for 1 hour, then keep for
24 ±1 hours at room temperature
No visual damage
ΔC/C
Class 1:
5 cycles with following detail:
30 minutes at lower category temperature
30 minutes at upper category temperature
NP0: within ±1% or 1 pF, whichever is greater
Class II:
X7R: ±15%
Recovery time 24 ±2 hours
D.F. meet initial specified value
I.R. meet initial specified value
Damp Heat
with Ur Load
IEC 60384- 4.13
21/22
No visual damage after recovery
1. Preconditioning, class II only:
150 +0/-10 °C /1 hour, then keep for
24 ±1 hour at room temp
ΔC/C
Class 1:
2. Initial measure:
Spec: refer initial spec C, D, I.R.
NP0: within ±2% or 1 pF, whichever is greater
3. Damp heat test:
500 ±12 hours at 40 ±2 °C;
90 to 95% R.H. 1.0 Ur applied
Class II:
X7R: ±15%
D.F.
4. Recovery:
Class 2: 24 ±2 hours
Class 1:
5. Final measure: C, D, I.R.
NP0: ≤ 2 x specified value
Class II:
P.S. If the capacitance value is less than the
minimum value permitted, then after the other
measurements have been made the capacitor
shall be precondition according to “IEC 60384
4.1” and then the requirement shall be met.
X7R: ≤ 2 x specified value
I.R.
Class 1:
NP0: ≥ 2,500 MΩ or
R x C ≥ 25Ω.F whichever is less
Class II:
X7R: ≥ 500 MΩ or
R x C ≥ 25Ω.F whichever is less
X7R/0805/4.7µF/16V ;
ΔC/C
X7R/1206/10µF/16V to 25V ;
±20%
X7R/1210/2.2µF to 10µF/16V to 50V,
X7R/1210/2.2µF/100V ;
D.F.
≤ 2 ꢀ specified value
I.R.
R ꢀ C ≥ 5 Ω.F
www.yageo.com
Jun. 19, 2017 V.4