Electrical data
Impedance, differential mode
Frequency
100 differential signalling, for one pair or quad cable shielded
DC to 2.0 GHz
20 dB to 1.0 GHz
17 dB to 2.0 GHz
0.1 dB @ 1.0 GHz
5 psec.
Return loss
Insertion loss
Skew (between signal contacts)
Nearend-Crosstalk
30 dB
Farend-Crosstalk
35 dB
Insulation resistance
Signal contact resistance
Outer contact resistance
Test voltage
1x103 M
10 m
7.5 m
250 V rms
Working voltage
100 V rms
Power current
1.5 A DC
RF-leakage ( shielding effectiveness )
75 dB up to 1 GHz (IEC 62153-4-7)
65 dB up to 2 GHz (IEC 62153-4-7)
- Limitations are possible due to the used cable type –
Mechanical data
Mating cycles
25
TBD
TBD
Engagement force
Disengagement force
Retention force latch
Retention force primary lock
Coding efficiency
Preliminary
110 N
80 N
80 N
Environmental data
Temperature range
Thermal shock
Temperature and humidity
Vibration (Random)
Mechanical Shock
High-Temp. Exposure
RoHS
-40°C to +105°C
DIN IEC 60068-2-14 Test NA
USCar 2 – 4 5.6.2
DIN IEC 60068-2-64
DIN IEC 60068-2-27
DIN IEC 60068-2-2
compliant
Tooling
Crimping tool
Crimp insert
on request
on request
Suitable cables
Dacar 535
Rosenberger Hochfrequenztechnik GmbH & Co. KG