To Be Discontinued
Last time buy: September 30, 2018
HL
RATING
1. Coil data
1) AC coils
Nominal coil current
(mA)
Nominal operating power
(VA)
Max. applied
voltage
(at 70°C 158°F)
Inductance (H)
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
50Hz
224
60Hz
200
50Hz
60Hz
When drop-out When operating
6V AC
12V AC
0.078
0.312
1.243
4.974
23.75
27.19
85.98
0.074
0.295
1.181
4.145
20.63
25.57
81.76
111
100
24V AC
56
50
80%V or less of
nominal voltage
(Initial)
30%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
48V AC
28
25
1.3
1.2
100/110V AC
110/120V AC
200/220V AC
13.4/14.7
12.2/13.5
6.7/7.4
12/13.2
10.9/11.9
6/6.6
Notes: 1. The relay operates in a range of 80% to 110% V of the nominal voltage, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
rated voltage.
In particular, for AC operation, if the applied voltage drops to 80% V or more below the nominal voltage, humming will occur and a large current will flow leading
possibly to coil burnout.
2. The maximum applied voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.)
2) DC coils (at 20°C 68°F)
Nominal coil
Nominal coil current
Nominal operating
power (W)
Coil resistance
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Max. applied voltage
(at 70°C 158°F)
voltage
(mA)
(Ω)
6V DC
12V DC
150
75
40
160
80%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
0.9
110%V of
nominal voltage
24V DC
37
650
48V DC
18.5
10
2,600
10,000
100/110V DC
1.0
Notes: 1. The nominal operating current is 10% (20°C 68°F).
2. The coil resistance for DC operation is the value measured when the coil temperature is 20°C 68°F. Compensate 0.4% for every 1°C change in temperature.
3. The relay operates in a range of 80% to 110% V of the nominal voltage, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
nominal voltage.
4. For use with 200 V DC, connect a 10 KΩ (5W) resistor, in series, to the 100 V DC relay.
5. The maximum applied voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.)
2. Specifications
Characteristics
Item
Contact resistance (Initial)
Contact material
Specifications
Max. 50 mΩ (By voltage drop 6 V DC 1A)
AgSnO2 type
Contact
1 Form C: 15A 125V AC, 10A 250V AC (resistive load)
2 Form C: 10A 250V AC (resistive load)
Nominal switching capacity*4
Rating
Min. switching capacity (Reference value)*1
Insulation resistance (Initial)
100mA 5V DC
Min. 100MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
1,000 Vrms for 1min. (Detection current: 10mA)
1,500 Vrms for 1min. (Detection current: 10mA)
2,000 Vrms for 1min. (Detection current: 10mA)
Max. 80°C 176°F (By resistive method, nominal voltage)
Between open contacts
Breakdown voltage
Between contact sets
(Initial)
Between contact and coil
Temperature rise (coil)
Electrical
characteristics
DC type/AC type: Max. 25ms
(Nominal coil voltage applied to the coil, excluding contact bounce time.)
Operate time (at 20°C 68°F)*2
Release time (at 20°C 68°F)*2
DC type/AC type: Max. 25ms
(Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode)
Functional
Shock resistance
Min. 196 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
Destructive
Mechanical
characteristics
Functional
Vibration resistance
Destructive
10 to 55 Hz at double amplitude of 1 mm (Detection time: 10μs.)
10 to 55 Hz at double amplitude of 2 mm
Mechanical
AC type: 5×107 (at 180 times/min.), DC type: 108 (at 180 times/min.)
1 Form C: 15A 125V AC, 10A 250V AC resistive load (cosϕ=1) Life switching cycle: Min. 5×105
AC load
Electrical
Expected life
2 Form C: 10A 250V AC resistive load (cosϕ=1) Life switching cycle: Min. 3×105
1 Form C: 3A 30V DC resistive load (cosϕ=1) Life switching cycle: Min. 5×105
2 Form C: 3A 30V DC resistive load (cosϕ=1) Life switching cycle: Min. 5×105
DC load
Ambient temperature: –50°C to +70°C –58°F to +158°F (Without LED indication);
Conditions for operation, transport and storage*3 –50°C to +60°C –58°F to +140°F (With LED indication)
Conditions
Unit weight
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 times/min. (at max. rating)
Approx. 35g 1.23 oz
Max. Operating speed
Notes: If integrating into electrical appliances that will be subject to compliance to the Electrical Appliance and Material Safety Law, please use in an ambient temperature
between –50°C to +40°C –58°F to +104°F (AC type).
*1. This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. For the AC coil types, the operate/release time will differ depending on the phase.
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*4. When using the socket, be sure to verify the max. continuous current.
ASCTB114E 201709-T