HP Series
120 - 192 W 10:1 DC-DC Converters
Part Number Description
H P 4 6 60 -9 R B1 G
Continuous operating input voltage Vi:
16.8 to 137.5 VDC ............................................... H
Series
..............................................................................P
Number of outputs:
Single output (160 mm case) 4.............................. 1
Double output (160 mm case) 4 ............................ 2
Triple output (160 mm case) 4............................... 3
Quadruple output (160 mm case) 4....................... 4
Nominal voltage output 1/output 4, Vo1/4 nom
:
5.1 V ..................................................................... 0
12 V ...................................................................... 3
15 V ...................................................................... 5
24 V ...................................................................... 6
other voltages1 ................................................. 7, 8
Other specifications and additional features1 ............. 01, ... 99
Nominal voltage output 2/output 3, Vo2/3 nom
:
5.1 V ................................................................... 01
12 V .................................................................... 20
15 V .................................................................... 40
24 V .................................................................... 60
other voltages and features1 .................... 80, ... 99
Operational ambient temperature range TA:
–40 to 71 °C ........................................................-9
other1 .................................................................. 0
Output voltage adjust (auxiliary function) ..............................R3
Options: Current sharing................................................... T2
UVL (preadjusted Vi min)................................... Uxx5
V (rotary switch to adjustVi min)............................V 6
Heatsink 10, 20, 30 mm.........................B0, B1, B3
RoHS-compliant for all 6 substances ......................................G
1
Customer-specific models.
2
Only available for single-output powertrains. Option T excludes option R, except for single-output models; refer to table 12.
T is standard for single-output models
The R-input influences the first power train only; refer to table 12.
Models with 220 mm case length. Just add 5000 to the standard model number, e.g. HP3020-9RG → HP8020-9RG.
For full compatibility with former P Series, the start voltage can be preadjusted depending on the nominal battery voltage. Excludes opt. V.
Excludes opt. U.
3
4
5
6
Note: The sequence of options must follow the order above.
Example: HP4660-9RB1G: DC-DC converter, input voltage 16.8 to 137.5 V, 4 outputs providing 24V each, heatsink B1,
ambient temperature of –40 to 71°C, RoHS-compliant.
Note:All models exhibit the following auxiliary functions, which are not reflected in the type designation: input and output filters, primary referenced
PUL (programmable undervoltage shutdown with inhibit function), sense lines (single-, double-, triple-output models only), and LED indicators.
Product Marking
Basic type designation, approval marks, CE mark, warnings, pin allocation, patents, MELCHER logo, specific type designation,
input voltage range, nominal output voltages and output currents, degree of protection, identification of LEDs, batch no., serial no.
and data code including production site, version, and production date.
tech.support@psbel.com
belfuse.com/power-solutions
BCD.00316 Rev AM, 25-Feb-2019
© 2019 Bel Power Solutions & Protection
Page 3 of 27