1000W Single Output with PFC Function
HRPG-1000 series
SPECIFICATION
MODEL
HRPG-1000-12
HRPG-1000-15
HRPG-1000-24
HRPG-1000-48
DC VOLTAGE
12V
15V
24V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
80A
64A
42A
21A
0 ~ 80A
0 ~ 64A
0 ~ 42A
0 ~ 21A
1008W
250mVp-p
46 ~ 56V
1.0%
960W (max. 1000W for 3 sec.) 960W (max. 1000W for 3 sec.) 1008W
RIPPLE & NOISE (max.) Note.2 150mVp-p
150mVp-p
200mVp-p
22 ~ 28V
1.0%
OUTPUT
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3
LINE REGULATION
11 ~ 14V
14 ~ 17V
2.0%
1.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
SETUP, RISE TIME
2.0%
1.5%
0.5%
0.5%
1000ms, 50ms/230VAC
2000ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC
16ms/115VAC at full load
VOLTAGE RANGE
Note.4 90 ~ 264VAC(300VAC for 5 sec.)
127 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
47 ~ 63Hz
PF>0.95/230VAC
91.5%
PF>0.99/115VAC at full load
92%
INPUT
93%
94%
8.5A/115VAC
25A/115VAC
<1.2mA / 240VAC
5A/230VAC
40A/230VAC
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
14.5 ~ 16.5V 18.2 ~ 20.6V 29 ~ 33V
Protection type : Shut down o/p voltage, re-power on to recover
OVERLOAD
58 ~ 65V
PROTECTION
FUNCTION
ENVIRONMENT
OVER VOLTAGE
Shut down o/p voltage, recovers automatically after temperature goes down
Up to 4000W or (3+1) units. Please refer to the Function Manual.
OVER TEMPERATURE
CURRENT SHARING
REMOTE ON-OFF CONTROL
REMOTE SENSE
Power ON : short; Power OFF : open. Please refer to the Function Manual.
Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual.
The TTL signal out, PSU turn on = 3.3 ~ 5.6V ; PSU turn off = 0 ~ 1V. Please refer to the Function Manual.
5VSB : 5V@0.3A ; tolerance 5%, ripple : 50mVp-p(max.)
Fan on/off by NTC(RT50) or 30% load min.
DC-OK SIGNAL
5V STANDBY
FAN CONTROL
-40 ~ +70℃ (Refer to "Derating Curve")
WORKING TEMP.
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +85℃, 10 ~ 95% RH non-condensing
0.03%/℃ (0 ~ 50℃)
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
UL62368-1, TUV EN62368-1, EAC TP TC 004 approved
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
Parameter
Conducted
Radiated
Standard
Test Level / Note
EN55032 (CISPR32) / EN55011 (CISPR11) Class B
EN55032 (CISPR32) / EN55011 (CISPR11) Class A
EMC EMISSION
Harmonic Current
Voltage Flicker
EN55024, EN61000-6-2
Parameter
ESD
EN61000-3-2
EN61000-3-3
Class A
-----
SAFETY &
Standard
Test Level / Note
EMC
(Note 7)
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
Level 3, 8KV air ; Level 2, 4KV contact
Radiated
Level 3
EFT / Burst
Surge
Level 3
EMC IMMUNITY
Level 4, 2KV/Line-Line 4KV/Line-Earth
Conducted
Magnetic Field
Level 3
Level 4
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
Voltage Dips and Interruptions
EN61000-4-11
MTBF
286.6K hrs min. Telcordia SR-332 (Bellcore) ; 105.8K hrs min. MIL-HDBK-217F (25℃)
218*105*63.5mm (L*W*H)
OTHERS
NOTE
DIMENSION
PACKING
1.53Kg;8pcs/13.3Kg/1.34CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the derating curve for more details.
5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
6. No load power consumption<0.75W when RC+ & RC- (CN100 pin3,4) open.
7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a 360mm*700mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
File Name:HRPG-1000-SPEC 2018-05-04