Preliminary
303.825 MHz Hybrid Transmitter
HX3001B
Ideal for 303.825 MHz Unlicensed Transmitters in Europe
Transmission Rates of Up to 10 kbps
Compact, Surface–Mount Case with <110mm2 Footprint
The HX3001B is a miniature hybrid transmitter designed for data transmission using
on–off keyed (OOK) modulation. The transmitter is stabilized by a quartz SAW device
for long–term frequency stability. The HX3001B is recommended for data rates up to
10 kbps (100 µsec bit period). The HX3001B is designed for unlicensed
remote–control and security transmiters operating in the USA under FCC Part 15 and
in Austrailia under DTC regulations.
SM10996–4 Case
ElectricalCharacteristics
Characteristic
Sym
Notes Minimum
Typical
Maximum Units
Operating Frequency
Absolute Frequency
Tolerance from 303.825 MHz
RF Output Power into 50 Ω at 25°C
Within Specified Temperature Range
f
1, 2, 3, 4
303.725
303.925
MHz
kHz
O
∆f
±200
O
P
2, 4, 5
–3
–5
0
0
dBm
O
2, 3, 4, 5
2, 3, 4, 5
Harmonic Spurious Emissions
Modulation Input
–40
dBc
V
Input HIGH Voltage
Input LOW Voltage
Input HIGH Current
Input LOW Current
V
2.5
0.0
V
CC
IH
V
3, 4, 5
0.3
IL
I
IH
100
µA
I
IL
0.0
18
Dynamic Input Resistance
Data Timing Parameters
5
kΩ
kHz
µs
Modulation Bandwidth
Modulation Rise Time
Modulation Fall Time
Voltage
5
20
20
3
t
R
3, 4, 5, 6
t
F
Power Supply
V
5, 7
3, 4, 5, 8
5, 9
2.7
3.3
10
VDC
mA
µA
CC
CC
Peak Current
I
7
Standby Current
1.0
+85
Operating Case Temperature Range
T
5
–40
°C
C
Lid Symbolization (in addition to Lot and/or Date Codes)
RFM HX3001B
CAUTION: Electrostatic Sensitive Device. Observe precautions for handling.
Notes:
1. One or more of the following United States patents apply:
8. The maximum operating current occurs at the maximum specified
power supply voltage and maximum specified operating tempera-
ture.
4,454,488; 4,616,197; 4,670,681; and 4,760,352.
9. Standby current is defined as the supply current consumed with
the modulation input at logic LOW.
2. Typically, equipment utilizing this device requires emissions test-
ing and government approval, which is the responsibility of the
equipment manufacturer.
3. Applies over the specified range of operating temperature.
Absolute Maximum Ratings
4. Applies over the specified range of operating power supply volt-
age.
5. The design, manufacturing process, and specifications of this
device are subject to change without notice.
Rating
Value
10
Units
V
6. The maximum modulation bandwidth (and data rate) is dependent
on the characteristics of the external encoding circuitry (not in-
cluded).
Power Supply and/or Modulation Input Voltage
Nonoperating Case Temperature
–40 to +100
230
°C
7. Unless noted otherwise, case temperature T = +25°C ± 2°C, test
C
Ten–Second Soldering Temperature
°C
load impedance = 50 Ω, and modulation input is at logic HIGH.