X9313
ABSOLUTE MAXIMUM RATINGS
Temperature under bias ....................–65
°
C to +135
°
C
Storage temperature .........................–65°C to +150°C
Voltage on CS, INC, U/D, V
H
, V
L
and
V
CC
with respect to V
SS
......................... –1V to +7V
∆
V = |V
H
–V
L
|
X9313Z ................................................................... 4V
X9313W, X9313U, X9313T ................................... 10V
Lead temperature (soldering 10 seconds)..........300°C
I
W
(10 seconds) .............................................. ±8.8mA
RECOMMENDED OPERATING CONDITIONS
Temperature
Commercial
Industrial
COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only; functional operation of the
device (at these or any other conditions above those
listed in the operational sections of this specification)
is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device
reliability.
Min.
0°C
–40°C
Max.
+70°C
+85°C
Supply Voltage (V
CC
)
X9313
X9313-3
Limits
5V ±10%
3V to 5.5V
POTENTIOMETER CHARACTERISTICS
(Over recommended operating conditions unless otherwise stated.)
Limits
Symbol
V
VH
V
VL
Parameter
End to end resistance tolerance
V
H
terminal voltage
V
L
terminal voltage
Power rating
Power rating
Min.
–5V
–5V
Typ.
Max.
±20
+5V
+5V
10
16
Unit
%
V
V
mW
mW
Ω
mA
dBV
%
Test Conditions/Notes
R
TOTAL
≥
10 KΩ
R
TOTAL
= 1 KΩ
I
W
= 1mA, V
CC
= 5V
Ref: 1kHz
R
w(n)(actual)
–R
w(n)(expected)
R
w(n+1)
–[R
w(n)+MI
]
R
W
I
W
Wiper resistance
Wiper current
Noise
Resolution
Absolute linearity
(1)
Relative linearity
(2)
R
TOTAL
temperature coefficient
Ratiometric temperature coefficient
40
-120
3
100
±4.4
±1
±0.2
±300
±20
10/10/25
MI
(3)
MI
(3)
ppm/°C
ppm/°C
pF;
C
H
/C
L
/C
W
Potentiometer capacitances
See Circuit #3
Notes:
(1) Absolute linearity is utilized to determine actual wiper voltage versus expected voltage = (V
w(n)
(actual)–V
w(n)
(expected)) = ±1 Ml
Maximum.
(2) Relative linearity is a measure of the error in step size between taps = R
W(n+1)
–[R
w(n)
+ Ml] = ±0.2 Ml.
(3) 1 Ml = Minimum Increment = R
TOT
/31.
REV 1.1 10/23/00
www.xicor.com
Characteristics subject to change without notice.
4 of 10
This Material Copyrighted by Its Respective Manufacturer