AS-i base
Dimensions
112
77.5
4
48
Model number
U-G2FF
Mounting base for connection to flat
cable (AS-i and external auxiliary vol-
tage)
Technical data
Ambient conditions
Ambient temperature
Storage temperature
Mechanical specifications
Protection degree
Connection type
Dimensions
-25 ... 60 °C (248 ... 333 K)
-25 ... 85 °C (248 ... 358 K)
IP67 based on EN 60529
(only in connection with module or cover)
AS-i flat cable
about 80, 45, 34 mm (L, W, H)
Function
The U-G2FF base is used for the connec-
tion of the G2 modules with long design to
AS-Interface. n case of mounting the modu-
le the inserted flat cables are pressed into
the contact prongs of the module and con-
nected. For some modules this upper part
establishes the connection to earth.
Electrical connection
AS-i
+
-
External
+
auxiliary
power
-
12
PE
+
-
+
-
Contacts to module
Accessories
Subject to reasonable modifications due to technical advances.
Copyright Pepperl+Fuchs, Printed in Germany
343
Pepperl+Fuchs Group • Tel.: Germany (06 21) 7 76-0 • USA (330) 4 25 35 55 • Singapore 7 79 90 91 • Internet http://www.pepperl-fuchs.com
Ausgabedatum
22.01.2002