ZXRE1004
ABSOLUTE MAXIMUM RATINGS
Reverse Current
Forward Current
Operating temperature.
Storage temperature.
30mA
10mA
-40 to 85°C
-55 to 125°C
Power Dissipation (T
amb
=25°C)
SOT23
330mW
SO8
625mW
E-Line
500mW
ELECTRICAL CHARACTERISTICS
TEST CONDITIONS (Unless otherwise stated) T
amb
=25°C
SYMBOL
PARAMETER
CONDITIONS
LIMITS
MIN
TYP
1.22
1.22
1.22
1.22
4
0.008
I
R(min)
to I
R(max)
20
MAX
1.226
1.232
1.244
1.257
8
20
75
0.5 ‡
1
2
3
V
TOL. %
UNITS
I
R
T
C
†
Recommended Operating
Current Range
Average Reverse Breakdown
Voltage Temperature
Coefficient
Reverse Breakdown Voltage
change with Current
Reverse Dynamic Impedance
mA
ppm/°C
I
R
10
Note: V
R(max)
- V
R(min)
is the maximum
deviation in reference voltage
measured over the full operating
temperature range.
‡ Note: 0.5% SOT23 only
T
C
V
R
x T
m ax
T
m in
†
m ax
min
V
R
V
R
x
1000000
2
Reverse Current ( A)
8
6
4
2
0
0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
-40°C
25°C
85°C
Reverse Voltage (V)
Reverse Characteristics
ISSUE 2 - JUNE 1999
E
N
Wideband Noise Voltage
I
R
=8 A to 100 A
f=10Hz to 10kHz
60
Z
R
I
R
=1mA
f =100Hz
I
AC
=0.1 I
R
V
R
I
R
=8 A to 1mA
I
R
=1mA to 20mA
0.2
1
10
0.6
mV
mV
I
MIN
Minimum Knee Current
V
R
Reverse Breakdown Voltage
I
R
=100 A
1.214
1.208
1.196
1.183
A
V (rms)