Series EZ
5-18Amp • 120/240, 480 Vac • AC Output
Low Leakage
Quick Connect Terminals
SCR Output
24V Control Available
(EZE Models)
nect terminals. The Series EZ is the
preferred choice for replacement of
120V and 240V Electro-mechanical
relays. Output consists of an SCR
switch and is available in Zero-Cross
and Random Turn-On (Phase
Controlable) versions.
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
The Series EZ SPST-NO AC output
relays offer a low profile package
with the convenience of quick con-
OUTPUT SPECIFICATIONS
Operating Voltage (47-63 Hz) [Vrms]
Max. Load Current
[Arms]
Min. Load Current, [mArms]
Transient Overvoltage [Vpk]
Max. Surge Current, (16.6ms) [Apk]
AC CONTROL
(120Vac)
(24Vac)
MODEL NUMBERS
DC CONTROL
(5Vdc)
(24Vdc)
EZ240A12
EZE240A12
EZ240D5
24-280
5
150
600
40
1.5
2.0
95
0.1
500
EZ240D12
EZE240D12
24-280
12
150
600
150
1.5
2.0
95
0.1
500
EZ240A18
EZE240A18
EZ240D18
EZE240D18
24-280
18
150
600
200
1.5
1.1
170
0.1
500
EZ480A12
EZE480A12
EZ480D12
EZE480D12
48-660
12
150
1200
150
1.5
2.0
95
0.1
500
EZ480A18
EZE480A18
EZ480D18
EZE480D18
48-660
18
150
1200
200
1.5
1.1
170
0.1
500
Max. On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (R
θJC
[˚C/W]
)
Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec]
Max. Off-State Leakage Current @
Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/ µsec]
Max. Turn-On Time
Max. Turn-Off Time
Power Factor (Min.) with Max. Load
0.5
1/2 Cycle (DC Input), 10.0 msec (AC Input)
1/2 Cycle (DC Input), 40.0 msec (AC Input)
0.5
0.5
0.5
0.5
INPUT SPECIFICATIONS
Nominal Voltage
MODEL NUMBERS
EZ240D05
Control Voltage Range
Max. Turn-On Voltage
Min. Turn-Off Voltage
Nominal Input Impedance
Typical Input Current @ Nominal Voltage
DC CONTROL
5Vdc
5Vdc
5Vdc
24Vdc
EZE240D12
EZE240D18
EZE480D12
EZE480D18
15-32 Vdc
15.0 Vdc
1.0 Vdc
1500 Ohms
15 mAdc
AC CONTROL
120Vac
EZ240A12
EZ240A18
EZ480A12
EZ480A18
90-140 Vrms
90.0 Vrms
10.0 Vrms
10.6k Ohms
10 mArms
24Vac
EZE240A12
EZE240A18
EZE480A12
EZE480A18
18-36 Vrms
18.0 Vrms
2.0 Vrms
1.8k Ohms
10 mArms
EZ240D12
EZ240D18
3-15 Vdc
3.0 Vdc
1.0 Vdc
300 Ohms
15 mAdc
EZ480D12
EZ480D18
4-15 Vdc
4.0 Vdc
1.0 Vdc
240 Ohms
15 mAdc
4-15 Vdc
4.0 Vdc
1.0 Vdc
300 Ohms
13 mAdc
GENERAL NOTES
©2002 CRYDOM CORP, Specifications subject to change without notice.
All parameters at 25˚ C unless otherwise specified.
Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
240V, DC control models only, all others 2500Vrms.
Heat sinking required, for derating curves see page 2.
For recommended applications and more information contact:
Off-State leakage for snubbered
USA: Sales Support
(877) 502-5500
Tech Support
(877) 702-7700
FAX
(619) 710-8540
version (suffix S) is 10.0 mArms.
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Turn-on time for random turn-on versions
Email:
sales@crydom.com
WEB SITE:
http://www.crydom.com
is 0.1 msec (DC Control Models).
UK:
+44 (0)1202 365070 •
FAX
+44 (0)1202 365090 Crydom International Ltd., 7 Cobham
FastFax Document No.160
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE,
Email:
intsales@crydom.com.
SERIES EZ.
GERMANY:
+49 (0)180 3000 506
REV. 031802
PAGE 1 OF 2