欢迎访问ic37.com |
会员登录 免费注册
发布采购

VRE104C 参数 Datasheet PDF下载

VRE104C图片预览
型号: VRE104C
PDF下载: 下载PDF文件 查看货源
内容描述: [VRE104]
分类和应用:
文件页数/大小: 5 页 / 251 K
品牌: ETC [ ETC ]
 浏览型号VRE104C的Datasheet PDF文件第2页浏览型号VRE104C的Datasheet PDF文件第3页浏览型号VRE104C的Datasheet PDF文件第4页浏览型号VRE104C的Datasheet PDF文件第5页  
VRE104
Precision
Reference Supplies
THALER CORPORATION • 2015 N. FORBES BOULEVARD • TUCSON, AZ. 85745 • (520) 882-4000
FEATURES
VERY HIGH ACCURACY: 4.5000 V OUTPUT ±0.4 mV
EXTREMELY LOW DRIFT: 0.6 ppm/°C -55°C to +125°C
EXCELLENT STABILITY: 6 ppm/1000 Hrs. Typ.
EXCELLENT LINE REGULATION: 6 ppm/V Typ.
WIDE SUPPLY RANGE: +13.5 to +22.0 V
HERMETIC 14-PIN CERAMIC DIP
MILITARY PROCESSING OPTIONS
APPLICATIONS
PRECISION A/D and D/A CONVERTERS
TRANSDUCER EXCITATION
ACCURATE COMPARATOR THRESHOLD
REFERENCE
HIGH RESOLUTION SERVO SYSTEMS
DIGITAL VOLTMETERS
HIGH PRECISION TEST and
MEASUREMENT INSTRUMENTS
DESCRIPTION
VRE104 Series Precision Voltage References
provide ultrastable +4.500 V outputs with up to
±0.4 mV initial accuracy and temperature
coefficient as low as 0.6 ppm/°C over the full
military temperature range.
These references are specifically designed to be
used with the Crystal Semiconductor line of
successive-approximation type Analog to Digital
Converters (ADCs). This line of ADCs sets new
standards for temperature drift, which can only be
as good as the external reference used. The
Thaler VRE104 combined with a Crystal ADC will
provide the lowest drift data conversion
obtainable.
SELECTION GUIDE
Type
VRE104C
VRE104CA
VRE104M
VRE104MA
Output
+4.5V
+4.5V
+4.5V
+4.5V
Temperature
Max. Volt
Operating Range Deviation
-25°C to +85°C
-25°C to +85°C
-55°C to +125°C
-55°C to +125°C
0.4mV
0.2mV
0.6mV
0.3mV
VRE104 series devices are available in two operating temperature ranges, -25°C to +85°C and -55°C to
+125°C, and two performance grades. All devices are packaged in 14-pin hermetic ceramic packages for
maximum long-term stability. "M" versions are screened for high reliability and quality.
Superior stability, accuracy, and quality make the VRE104 ideal for all precision applications which may
require a 4.5V reference. High-accuracy test and measurement instrumentation, and transducer excitation are
some other applications which can benefit from the high accuracy of the VRE104.
VRE104DS REV. C SEPT 1994