2N3867, S; 2N3868, S JAN SERIES
ELECTRICAL CHARACTERISTICS (con’t)
Characteristics
ON CHARACTERISTICS (3)
Symbol
Min.
Max.
Unit
Forward-Current Transfer Ratio
50
35
40
30
25
20
20
IC = 500 mAdc, VCE = 1.0 Vdc
2N3867, S
2N3868, S
2N3867, S
2N3868, S
2N3867, S
2N3868, S
All Types
200
150
IC = 1.5 Adc, VCE = 2.0 Vdc
IC = 2.5 Adc, VCE = 3.0 Vdc
hFE
IC = 3.0 Adc, VCE = 5.0 Vdc
Collector-Emitter Saturation Voltage
IC = 500 mAdc, IB = 50 mAdc
IC = 1.5 Adc, IB = 150 mAdc
0.5
0.75
1.5
Vdc
Vdc
VCE(sat)
IC = 2.5 Adc, IB = 250 mAdc
Base-Emitter Saturation Voltage
IC = 500 mAdc, IB = 50 mAdc
IC = 1.5 Adc, IB = 150 mAdc
1.0
1.4
2.0
VBE(sat)
0.9
3.0
IC = 2.5 Adc, IB = 250 mAdc
DYNAMIC CHARACTERISTICS
Magnitude of Common Emitter Small-Signal Short Circuit
Forward Current Transfer Ratio
12
½hfe½
IC = 100 mAdc, VCE = 5.0 Vdc, f = 20 MHz
Output Capacitance
VCB = 10 Vdc, IE = 0, 100 kHz £ f £ 1.0 MHz
Input Capacitance
pF
pF
Cobo
Cibo
120
800
VEB = 3.0 Vdc, IC = 0, 100 kHz £ f £ 1.0 MHz
SWITCHING CHARACTERISTICS
td
tr
ts
tf
Delay Time
VCC = -30 Vdc, VEB = 0,
35
65
hs
hs
hs
hs
Rise Time
IC = 1.5 Adc, IB1 = 150 mAdc
VCC = -30 Vdc, VEB = 0,
Storage Time
Fall Time
500
100
IC = 1.5Adc, IB1 = IB2 = 150 mAdc
Turn-On Time
VCC = 30, IC = 1.5 Adc, IB = 150 mAdc
Turn-Off Time
ton
100
600
hs
hs
toff
VCC = 30, IC = 1.5 Adc, IB = 150 mAdc
SAFE OPERATING AREA
DC Tests
TC = 250C, 1 Cycle, t = 1.0 s
Test 1
VCE = 3.33 Vdc, IC = 3.0 Adc
Test 2
VCE = 40 Vdc, IC = 160 mAdc
VCE = 60 Vdc, IC = 80 mAdc
2N3867, S
2N3868, S
(3) Pulse Test: Pulse Width = 300ms, Duty Cycle £ 2.0%.
6 Lake Street, Lawrence, MA 01841
1-800-446-1158 / (978) 794-1666 / Fax: (978) 689-0803
120101