2-3 Watts
xppower.com
JCA02/03 Series
•
•
•
•
•
•
•
Compact 1.0” x 0.8” Metal Package
Industry Standard Pinout
2:1 Input Range
Single & Dual Outputs
Operating Temperature -40 °C to +100 °C
1500 VDC Isolation
UL & TUV Approved
Specification
Input
General
Input Voltage Range
• 5 V (4.5-9.0 VDC)
12 V (9-18 VDC)
24 V (18-36 VDC)
48 V (36-75 VDC)
Efficiency
Isolation
• See table
• 1500 VDC Input to Output, basic insulation
500 VDC Input to Case
500 VDC Output to Case
Input Current
Input Filter
• See table
MTBF
• 400 kHrs to MIL-STD-217F
• Pi network
Environmental
Operating Temperature • -40 °C to +100 °C output power derates
froꢀ 100% load at +75 °C linearly to
Undervoltage Lockout • Turn On at >90-95% of rated input
Turn Off at <80% of rated input
Output
0% load at +100 °C
Case Temperature
• +100 °C ꢀaꢁ
Output Voltage
• See table
• 1% ꢀaꢁ
Storage Temperature
• -55 °C to +125 °C
Intial Set Accuracy
Start Up Delay
• 30 ꢀs ꢀaꢁ
EMC & Safety
Start Up Rise Time
Line Regulation
Load Regulation
Cross Regulation
Transient Response
• 3.5 ꢀs typical
Emissions
• EN55022, level A conducted
(level B with eꢁternal coꢀponents, see
application note), level B radiated
•
•
•
0.3%
1%
5% on dual output ꢀodels
ESD Immunity
• EN61000-4-2, level 2 Perf Criteria A
• EN61000-4-3, 3 V/ꢀ Perf Criteria A
• 4% ꢀaꢁ deviation, recovery to within
1% in <500 µs for a 25% load change
at 1 A/µs
Radiated Immunity
Conducted Immunity
• EN61000-4-6, 3 V rꢀs Perf Criteria A
EN61000-4-8, 10 A/ꢀ Perf Criteria A
Ripple & Noise
• 50 ꢀV pk-pk, 20 MHz BW
Safety Approvals
• EN60950-1: 2001, UL60950-1,
CSA C22.2 No. 60950-1-03,
CE Mark LVD
Overcurrent Protection • 120% typical, trip and restart
(Hiccup ꢀode)
Short Circuit Protection • Continuous with auto recovery
Overvoltage Protection • 120% typical, Recycle input to reset
Temperature
Coefficient
•
0.05%/°C