Ordering information
AC-DC Power Supplies Open Frame/ Enclosed Type
LG
A
100
A
-5
-O
6
LGA100A
1ꢀ
2ꢀ
3ꢀ
4ꢀ
5ꢀ
1Series name
2Single output
Example recommended EMI/EMC filter
NAC-06-472
R
3Output wattage
4100/120V input
5Output voltage
6Optional
C :with Coating
G :Low leakage current
H :with the function to be
acceptable to output
peak current (only 24V)
J1:VH(J.S.T.)connector
type
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*
Aꢀhigher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
S :with Chassis
SN:with Chassis & cover
Y :with Potentiometer
This power supply is manufactured by SMD technology.The stress to P.C.B like twisting or bending causes the defect of the unit,so handle the unit with care.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
LGA100A-3R3-Y LGA100A-5-Y LGA100A-12
LGA100A-15
105
15V 7A
LGA100A-24
103.2
24V 4.3A
LGA100A-24-H LGA100A-48
66
100
102
103.2
100.8
(
)
A
3.3V 20A
5V 20A
12V 8.5A
24V 4.3 Peak 5.4
48V 2.1A
SPECIFICATIONS
MODEL
LGA100A-3R3-Y LGA100A-5-Y LGA100A-12
LGA100A-15
LGA100A-24
LGA100A-24-H LGA100A-48
( )
Refer to "Derating", Instruction Manual 1 and 3
f
VOLTAGE[V]
CURRENT[A]
AC85 - 132 1
(
)
(
)
ACIN 100V 1.6typ Io=100%
2.4typ Io=100%
(
)
FREQUENCY[Hz]
EFFICIENCY[%]
47 - 440 Refer to Instruction Manual 1.1
INPUT
(
)
(
)
(
)
(
)
(
)
(
)
(
)
ACIN 100V 76.0typ Io=100%
80.0typ Io=100% 83.0typ Io=100%
84.0typ Io=100% 85.5typ Io=100% 85.5typ Io=100% 85.5typ Io=100%
(
)
INRUSH CURRENT[A] ACIN 100V 15typ Io=100%, More than 10sec. to re-start
(
,
)
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.5max ACIN 100V, 60Hz Io=100%, According to IEC60950-1 and DEN-AN
3.3
5
12
15
24
24
48
3
(
)
*
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
20.0
20.0
8.5
7.0
4.3
4.3 Peak 5.4
96max
2.1
20max
40max
80max
140max
120max
160max
50max
20max
40max
80max
140max
120max
160max
50max
60max
20max
48max
100max
120max
160max
150max
180max
120max
150max
48max
60max
120max
120max
160max
150max
180max
150max
180max
60max
96max
150max
120max
160max
150max
180max
240max
290max
96max
192max
300max
150max
200max
350max
400max
480max
600max
192max
150max
240max
320max
300max
360max
240max
290max
96max
1
*
1
*
1
*
1
*
0
to +50
C
RIPPLE[mVp-p]
-10 - 0
C
0
to +50
C
RIPPLE NOISE[mVp-p]
OUTPUT
-10 - 0
C
0 to +50
C
TEMPERATURE REGULATION[mV]
-10 to +50 60max
C
2
*
DRIFT[mV]
20max
(
,
)
START-UP TIME[ms]
HOLD-UP TIME[ms]
200max ACIN 100V Io=100%
(
,
)
20typ ACIN 100V Io=100%
( )
Fixed "Y"which can be adjusted the output is available as optional 10%
t
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.63
OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40
4.50 - 5.50
5.00 - 5.15
11.50 - 12.50
14.40 - 15.60
23.00 - 25.00
23.00 - 25.00
46.00 - 50.00
(
)
OVERCURRENT PROTECTION Works over 105% of rating works over 101% of peak current at option -H and recovers automatically
OVERVOLTAGE PROTECTION 4.00 - 5.25 5.75 - 7.00 13.80 - 16.80 17.30 - 21.00 27.60 - 35.00 27.60 - 35.00 55.20 - 67.20
PROTECTION
CIRCUIT AND OPERATING INDICATION
Not provided
Not provided
Not provided
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
,
,
,
(
)
)
AC2 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature
W
, , , (
AC2 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature
W
ISOLATION INPUT-FG
OUTPUT-FG
,
,
(
)
AC500V 1minute Cutoff current = 25mA DC500V 50M min At Room Temperature
W
,
,
C
(
) (
),
,
(
,
)
OPERATING TEMP. HUMID.AND ALTITUDE -10 to +60
20 - 90%RH Non condensing Refer to "Derating", Instruction Manual 3 3 000m 10 000feet max
,
,
(
),
,
(
,
)
STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75
20 - 90%RH Non condensing 9 000m 30 000feet max
C
ENVIRONMENT
2
,
(
),
,
,
VIBRATION
10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis
IMPACT
196.1m/s2 20G 11ms once each X Y and Z axis
),
(
,
,
SAFETY AND
NOISE
, ( )
UL60950-1 C-UL CSA60950-1 , EN60950-1 Complies with DEN-AN
AGENCY APPROVALS
CONDUCTED NOISE
CASE SIZE/WEIGHT
COOLING METHOD
,
,
,
,
Complies with FCC-B VCCI-B CISPR-B EN55011-B EN55022-B
REGULATIONS
( )
62 35.5 155mm [2.44 1.4 6.1 inches] W H D
X X
(
)
/ 300g max with chassis & cover : 530g max
X
X
X
X
OTHERS
(
)
Convection Refer to "Derating", Instruction Manual 3
*1 This is the value that measured on measuring board with capacitor of 22mF at 150mm from output terminal.
Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN: RM-103).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*3 Peak loading for 10sec.And Duty 35% max.or less is acceptable if the total wattage is less than the rated wattage.
ꢀ
Refer to instruction Manual 6. In detail.
*ꢀ Avoid prolonged use under over - load.
*ꢀ Parallel operation with other model is not possible.
*ꢀ Derating is required when operated with chassis and cover.
*ꢀ A sound may occur from power supply at pulse loading.
June 26, 2020
LGA-6