NLP40 Series
S i n g l e , d u a l a n d t r i p l e o u t p u t
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40-50W AC/DC Universal Input Switch Mode Power Supplies
1
• 4.25 x 2.5 x 1.15 inch package (1U applications)
• Smallest industry package
• Overvoltage and short circuit protection
• 40W with free air convection
• EN55022, EN55011 conducted emission level B
• EN61000-4-2, -3, -4, -5, -6 immunity compliant
• UL, VDE and CSA safety approvals
The NLP40 series is a 40W universal input AC/DC power supply on a 4.25 x 2.5 inch card
with a maximum component height of 1.15 inches for use in 1U applications. This
product is the smallest standard 40W package in the industry making the series ideal for
communication applications with space constraints where a standard 5 x 3 inch card
solution is not suitable. The NLP40 provides 40W of output power with free air convection
cooling which can be boosted to 50W with 20CFM of air. Standard features include
overvoltage and short circuit protection. The series, with full international safety approval
and the CE mark, meets conducted noise EN55022 level B and has immunity compliance
to EN61000-4-2,-3,-4, -5, -6. The NLP40 series is designed for use in low power data
networking, computer and telecom applications such as hubs, routers, POS terminals,
LCD projectors, cable modems and PABX’s. This list is not exclusive as the generic
feature set of the NLP40 series with industry standard output configurations provides a
solution for most low power applications including many industrial applications.
2 YEAR WARRANTY
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
SPECIFICATIONS
OUTPUT SPECIFICATIONS
GENERAL SPECIFICATIONS
Total regulation
(Line and load)
Main output
Auxiliary outputs
±2.0%
±5.0%
Hold-up time
120VAC
230VAC
12ms @ 40W
20ms @ 40W
Rise time
At turn-on
1.0s, max.
Efficiency
75% typical
Transient response
Main output
25% step at 0.1A/µs 1ms rec. to 1.0%
5.0% max. dev.,
Isolation voltage
Input/output
Input/chassis
3000VAC
1500VAC
Temperature coefficient
Overvoltage protection
Short circuit protection
±0.02% /°C
Switching frequency
Fixed
65kHz, ±5kHz
Main outputs
135% , ±15%
Continuous
Approvals and
standards (See Note 8)
EN60950, IEC950, UL1950
VDE0805, CSA C22.2 No. 950
Cyclic operation
Weight
200g (7.06oz)
Minimum output current Single
Multiple
0A
(See Note 5)
MTBF
MIL-HDBK-217F
150,000 hours min.
INPUT SPECIFICATIONS
ENVIRONMENTAL SPECIFICATIONS
Input voltage range
(See Note 9)
Universal input
90 to 264VAC
120 to 370VDC
Thermal performance
(See Notes 6, 7, 9)
Operating ambient,
(see derating curve)
0°C to +70°C
Non-operating
-40°C to +70°C
Input frequency range
Input surge current
47Hz to 440Hz
50°C to 70°C ambient,
convection cooled
0°C to 50°C, ambient,
convection cooled
0°C to 50°C ambient,
20CFM forced air
Derate to
50% load
40W
120VAC, cold start
230VAC, cold start
15A max.
30A max.
Safety ground
leakage current
120VAC, 60Hz
230VAC, 50Hz
0.2mA
0.4mA
50W
Peak (0°C to +50°C, 60s) (See Note 2)
Input current
120VAC
230VAC
1.4A rms
0.7A rms
Relative humidity
Altitude
Non-condensing
5% to 95% RH
Input fuse
UL/IEC127
250VAC H 3.15A
Operating
Non-operating
10,000 feet max.
30,000 feet max.
(10)
EMC CHARACTERISTICS
Vibration (See Note 4)
Shock
5Hz to 500Hz
2.4G rms peak
516.4 Part IV
Conducted emissions
Radiated emissions
ESD air
EN55022, FCC part 15
level B
level A
EN55022, FCC part 15
EN61000-4-2, level 3
EN61000-4-2, level 3
EN61000-4-5, level 3
EN61000-4-4, level 3
EN61000-4-3, level 3
EN61000-4-6, level 3
per MIL-STD-810E
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
Perf. criteria 1
ESD contact
Surge
Fast transients
Radiated immunity
Conducted immunity
File Name: NLP40.PDF Rev: 01 Jan 2000