Output Specification
Turn on time
2s max
at 90Vac (150Vac for 1500W) and 100% rated output power
240Vac & above 50% rated power, configuration dependent
Efficiency
up to 91%
20ms min
16ms min
at 1200W output power. 1 cycle ride-through option available, contact sales for details.
at 1500W output power
Hold up
converter protection shuts down all outputs (except standby supplies) and fan, auto
restarts. Shutdown temperature varies according to ambient, output power and input voltage.
Over temperature protection
Yes
Environment
Temperature
-20°C to 70°C operational, -40°C to 70°C storage.
50°C to 70°C derate total output power and each output current by 2.5% per °C
Additionally, the 0.25A standby supply provided with the E5H, E12H, T5H and T12H options derates by 2.4% per °C from
25°C to 50°C when the unit is inhibited (fan not running)
Derating
Low temperature startup
Humidity
-40°C
5 - 95% RH non condensing
±3 x 30g shocks in each plane, total 18 shocks (11ms (+/-0.5msec), half sine)
Conforms to EN60068-2-27, EN60068-2-47, IEC68-2-27, IEC68-2-47, JIS C0041-1987.
Conforms to MIL-STD-810G, Method 516.6, Pro IV
Shock
Single axis 10 - 500 Hz at 2g (sweep and endurance at resonance) in all 3 planes
Conforms to EN60068-2-6, IEC68-2-6
Vibration
Conforms to MIL-STD-810G, Method 514.6, Pro I
Altitude
Pollution
IP Rating
5000 metres operational, 5000 metres storage/transportation
Degree 2, Material group IIIb
IPX0
Emissions EN61000-6-3:2007, EN60601-1-2:2015 - see application notes for best installation practice
(as per CISPR.11/32) Class B, FCC47 part 15 subpart B - ‘L’ leakage current variants
(Units with ‘R’ type leakage current option achieve Class A)
Radiated electric field
EN55011, EN55032
(as per CISPR.11/32) Class B, FCC47 part 15 subpart B - ‘L’ leakage current variants
(Units with ‘R’ type leakage current option achieve Class A)
Conducted emissions
EN55011, EN55032
Conducted harmonics
Flicker
EN61000-3-2
EN61000-3-3
Class A and Class C
Compliant - dmax only
Immunity EN61000-6-2:2005, EN60601-1-2:2015 - see application notes for best installation practice
Criteria
F type cooling only
A
Electrostatic discharge
EN61000-4-2
Level 4
Proximity fields, EN60601-1-2, Levels as defined in
standard, Criteria A
Electromagnetic field
EN61000-4-3
Level 3
A
Tested at 5kHz and 100kHz
Fast / burst transient
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
Level 4
Level 3
Level 3
Level 4
Class 3
compliant
Level 3
3kV
A
A
A
A
A
Surge immunity
Conducted RF immunity
Power frequency magnetic field
Criteria B for 5s and 1 cycle interruptions
above 180Vac input
Voltage dips, variations, interruptions EN61000-4-11
Voltage sags
Semi F-47
EN61000-4-12
ANSI C62.41
EN61000-4-14
A
A
A
Ring wave
30Ω Neutral Grounding (0.5µs-100kHz Ring Wave)
See EMC report for full details.
Voltage fluctuations
Class 3
Approvals / Accreditations
IEC/EN 62368-1, UL62368-1 / CSA 22.2 No 62368-1
File E135494
File E135494
IEC/EN 60950-1, UL60950-1 / CSA 22.2 No 60950-1
IEC/EN 60601-1, UL/CSA 60601-1, ANSI/AAMI ES60601-1, CAN/CSA-C22.2 No 60601-1
IEC/EN 61010-1
File E349607
Designed to meet
Low Voltage Directive (LVD), electromagnetic compatibility (EMC) and Restriction
of Hazardous Substances (RoHS)
CE Mark (EN62368-1)
CB certificate and Report available on request
Designed and manufactured under the control of ISO9001 and ISO13485 (including risk management).
QM7FM_Datasheet_260275 - V18.0
3
QM7 Series