General Purpose Relays
Power PCB Relay RT1 Inrush Power
I
I
I
I
I
I
I
I
1 pole 16 A, 1 NO contact (W pre-make contact + AgSnO2)
10 A / 250 VAC making and breaking capacity acc. to IEC 60669-1
165 A / 20 ms inrush peak current
Mono- or bistable coil
5 kV / 10 mm coil-contact
Reinforced insulation
Optional test tab (manual operator)
RoHS compliant (Directive 2002/95/EC)
Applications
Lighting systems, movement sensors, filament and incandescent lamp loads,
motors
F0272-A
Approvals
V
REG.-Nr. 6106,
Z
E214025
Technical data of approved types on request
Contact data
RT.3T
RTS3L
Contact configuration
1 NO
pre-make contact
Contact set
single contact
Type of interruption
micro disconnection
Rated current
16 A
250/400 VAC
16 A
Rated voltage / max.switching voltage AC
Limiting continuous current
Maximum breaking capacity AC
Limiting making capacity
max 20 ms (incandescent lamps)
max 200 μs (fluorescent lamps)
Contact material
4000 VA
165 A
800 A
120 A
-
W (pre-make cont.)+AgSnO2 AgSnO2
Mechanical endurance DC
bistable
tab manually operated
Rated frequency of operation with / without load
> 5x106 cycles
> 3x106 cycles
> 103 cycles
> 10x106 cycles
> 5x106 cycles
-
6 / 60 min-1
Contact ratings
Type
Load
Cycles
RTS3T 3000 W, 230 VAC, DF 8,3%, 5 min-1, incandescent lamp
typ. 12x103
> 20x103
25x103
RT*3T
RT*3T
16 A, 250 VAC, capacitive load 140 μF, 7,5 min-1, EN60669-1
TV5, UL508, 40°C
RTS3L 16 A, 250 VAC, 85°C
> 100x103
RTS3L 1.5 hp, 240 VAC
RTS3L TV8, UL508, 40°C
RTS3L 10/100 A / 250 VAC, simulated lamp load, acc. to IEC 61810-2
25x103
20x103
Coil data
Coil data, monostable coil
Rated coil voltage range
Coil power
Operative range
Coil insulation system according UL1446
5...110 VDC
typ 400 mW
2
class F
Coil versions, monostable DC-coil
Coil
Rated
voltage
VDC
5
Operate
voltage
VDC
3.5
Release
voltage
VDC
0.5
Coil
resistance
c
62+10%
90+10%
360+10%
1440+10%
5520+10%
8570+12%
28800+12%
Rated coil
power
mW
code
005
006
012
024
048
060
110
403
6
4.2
0.6
400
12
8.4
1.2
400
24
16.8
33.6
42.0
77.0
2.4
400
48
4.8
417
60
6.0
420
110
11.0
420
All figures are given for coil without preenergization, at ambient temperature +23°C
Other coil voltages on request
1
Datasheet
Rev. EK1
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Issued 2005/11
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
www.tycoelectronics.com
www.schrackrelays.com
Specifications subject to
change.