TL3x071, TL3x071A, TL3x072, TL3x072A, TL3x074, TL3x074A
HIGH-SLEW-RATE, SINGLE-SUPPLY OPERATIONAL AMPLIFIERS
SLOS097C – MARCH 1991 – REVISED AUGUST 1996
†
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
Supply voltage, V
(see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –22 V
CC+
CC–
Differential input voltage, V (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±44 V
ID
Input voltage, V (any input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V
I
CC±
Input current, I (each input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±1 mA
I
Output current, I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±80 mA
O
Total current into V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 mA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 mA
CC+
CC–
Total current out of V
Duration of short-circuit current at (or below) 25°C (see Note 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . unlimited
Continuous total power dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating Table
Operating free-air temperature range, T : TL3307x . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –40°C to 105°C
A
TL3407x . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
TL3507x . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –55°C to 125°C
Storage temperature range, T
Lead temperature 1.6 mm (1/16 inch) from case for 10 seconds: D, DW, N, or P package . . . . . . . . . 260°C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
stg
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values, except differential voltages, are with respect to the midpoint between V
CC+
and V
.
CC–
2. Differential voltages are at the noninverting input with respect to the inverting input. Excessive current flows if input is brought below
–0.3 V.
V
CC–
3. The output can be shorted to either supply. Temperature and/or supply voltages must be limited to ensure that the maximum
dissipation rating is not exceeded.
DISSIPATION RATING TABLE
T
≤ 25°C
DERATING FACTOR
T
= 70°C
T
= 105°C
T = 125°C
A
A
A
A
PACKAGE
POWER RATING
ABOVE T = 25°C
POWER RATING POWER RATING POWER RATING
A
D
DW
N
725 mW
1025 mW
1150 mW
1000 mW
5.8 mW/°C
8.2 mW/°C
9.2 mW/°C
8.0 mW/°C
464 mW
656 mW
736 mW
640 mW
261 mW
369 mW
414 mW
360 mW
145 mW
205 mW
230 mW
200 mW
P
recommended operating conditions
TL3307x
TL3407x
TL3507x
UNIT
V
MIN
±2
MAX
±22
2.7
MIN
±2
0
MAX
±22
2.9
MIN
±2
MAX
Supply voltage, V
±22
2.7
CC±
V
V
= 5 V
0
0
CC
Common-mode input voltage, V
V
IC
Operating free-air temperature, T
= ±15 V
–15
–40
12.7
105
–15
0
12.9
70
–15
–55
12.7
125
CC±
°C
A
3
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265