TLJ Series
Tantalum Solid Electrolytic Chip Capacitors -
High CV Consumer Series
QUALIFICATION TABLE – CATEGORY 1
TLJ series (Temperature range -55ºC to +125ºC)
TEST
Condition
Characteristics
no visible damage
2 x initial limit
Visual examination
DCL
Apply rated voltage (Ur) at 40ºC and / or category
voltage (Uc) at 85ºC for 2000 hours through a circuit
impedance of ≤0.1Ω/V. Stabilize at room temperature
for 1-2 hours before measuring.
Endurance
ΔC/C
ESR
within ±10% of initial value
1.25 x initial limit
Visual examination
no visible damage
2 x initial limit
within ±10% of initial value
1.25 x initial limit
Store at 65ºC and 90-95% relative humidity for 500
hours, with no applied voltage. Stabilize at room
temperature and humidity for 1-2 hours before
measuring.
DCL
ΔC/C
ESR
Humidity
Step
Temperature°C
Duration(min)
+20ºC
2 x IL*
n/a
-55ºC
n/a
+20ºC
2 x IL*
±5%
+85ºC
+125ºC +20ºC
1
2
3
4
5
6
+20
-55
15
15
15
15
15
15
DCL
20 x IL*
25 x IL*
IL*
Temperature
Stability
+20
+85
+125
+20
ΔC/C
+0/-20%
+20/-0% +25/-0%
±5%
ESR
1.25 xIL* 2.5 x IL* 1.25 x IL* 1.25 x IL* 1.25 x IL* 1.25xIL*
no visible damage
2 x initial limit
within ±5% of initial value
1.25 x initial limit
Visual examination
DCL
ΔC/C
ESR
Apply 1.3x rated voltage (Ur) at 40ºC for 1000 cycles
of duration 6 min (30 sec charge, 5 min 30 sec
discharge) through a charge / discharge resistance
of 1000Ω
Surge
Voltage
Visual examination
no visible damage
DCL
ΔC/C
ESR
initial limit
within ±5% of initial value
initial limit
no visible damage
initial limit
Mechanical
Shock
MIL-STD-202, Method 213, Condition C
MIL-STD-202, Method 204, Condition D
Visual examination
DCL
ΔC/C
ESR
Vibration
within ±5% of initial value
initial limit
*Initial Limit
QUALIFICATION TABLE – CATEGORY 2
TLJ series (Temperature range -55ºC to +125ºC)
Characteristics
TEST
Condition
Visual examination
no visible damage
2 x initial limit
Apply rated voltage (Ur) at 40ºC and / or category
voltage (Uc) at 85ºC for 2000 hours through a circuit
impedance of ≤0.1Ω/V. Stabilize at room temperature
for 1-2 hours before measuring.
DCL
ΔC/C
ESR
Endurance
Humidity
within +5/-30% of initial value
1.25 x initial limit
Visual examination
no visible damage
2 x initial limit
within ±10% of initial value
1.25 x initial limit
Store at 65ºC and 90-95% relative humidity for 500
hours, with no applied voltage. Stabilize at room
temperature and humidity for 1-2 hours before
measuring.
DCL
ΔC/C
ESR
Step
Temperature°C
Duration(min)
+20ºC
2 x IL*
n/a
-55ºC
n/a
+20ºC
2 x IL*
±10%
+85ºC
+125ºC +20ºC
25 x IL* 2 x IL*
1
2
3
4
5
6
+20
-55
+20
+85
+125
+20
15
15
15
15
15
15
DCL
ΔC/C
ESR
20 x IL*
Temperature
Stability
+5/-20%
+20/-0% +25/-0% ±10%
1.25 xIL* 2.5 x IL* 1.25 x IL* 1.25 x IL* 1.25 x IL* 1.25xIL*
Visual examination
DCL
ΔC/C
ESR
Visual examination
DCL
ΔC/C
ESR
no visible damage
2 x initial limit
within ±5% of initial value
1.25 x initial limit
no visible damage
initial limit
within ±5% of initial value
initial limit
no visible damage
initial limit
Apply 1.3x rated voltage (Ur) at 40ºC for 1000 cycles
of duration 6 min (30 sec charge, 5 min 30 sec
discharge) through a charge / discharge resistance
of 1000Ω
Surge
Voltage
Mechanical
Shock
MIL-STD-202, Method 213, Condition C
MIL-STD-202, Method 204, Condition D
Visual examination
DCL
ΔC/C
ESR
Vibration
within ±5% of initial value
initial limit
*Initial Limit
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or
available online at www.avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
44
060920