YB1300
Regulated Charge Pump 5V 100mA
Functional Block
Cpump
CN
CP
4
6
Short-Circuit
Protection
Soft-Start
Circuit
VIN
VOUT
5
1
BOOST DRIVER
COUT
CIN
Current Bias
Generator
Boost Feedback &
Timing Control Block
Chip
Enable
Thermal
Protection
EN
3
1MHz
Oscillator
VREF
2
GND
Figure 9. Block Diagram
Functional Description
The YB1300 regulated charge pump
provides a regulated 5V output voltage for
input voltages between 2.7V and 5V. This is
accomplished by a step-up or boost mode
of operation. A conversion clock of 50%
duty cycle is generated. During the first half
cycle, the pumping capacitor CPUMP
charges to VIN. During the second half
cycle, the voltage on CPUMP is added to VIN,
then deliver to VOUT. The output voltage is
regulated by skipping clock cycles as
necessary.
limit inrush current at turn-on. When
starting up, the output capacitor is charged
through the charge-pump capacitor with a
limited current source. When the output
voltage approached to its design value, the
soft-start is terminated and normal
operation begins. If an overload condition
occurs, for example, the output is shorted
to ground, the output current is limited by
the YB1300 switching technique.
Thermal Protection
The regulator has thermal shutdown
circuitry that protects it from damage
caused by high temperature conditions.
The thermal protection circuitry shut down
Soft-Start and Short-Circuit Protection
Circuitry
The YB1300 includes soft-start circuitry to
YB1300 MRev.1.2
WWW.YOBON.COM.TW
5